Legacy Lab SuppliesPO
🔍
SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V - Microplate Readers | Legacy Lab Supplies

SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V

$6,588.08$7,750.68Sale
💰 You save $1,162.60 vs MSRP
The MR9600-T is the incubation-equipped variant of the Accuris SmartReader 96 Microplate Absorbance Reader — combining the standard 96-well absorbance measurement with built-in plate incubation for temperature-controlled
1

Lead Time

6–10 Weeks

Delivery

Freight / White Glove

Warranty

Full Manufacturer Warranty Support

🔒

Authorization Hold — Not Charged Immediately

Your card is authorized at checkout. Final charge confirmed after shipping is arranged.

Download Quick View
SKU: MR9600-T

Looking at other brands too?

Compare this class of equipment spec-by-spec across our brands — same size, different manufacturer, honest guidance on which fits your application.

Compare Across Brands →

The MR9600-T is the incubation-equipped variant of the Accuris SmartReader 96 Microplate Absorbance Reader — combining the standard 96-well absorbance measurement with built-in plate incubation for temperature-controlled workflows. The incubation module enables kinetic assays (where absorbance is measured over time at a controlled temperature), enzyme-kinetics workflows (rate measurement at biological temperature, typically 37 °C), and cell-based microplate assays (where adherent or suspension cells must be maintained at culture temperature during the read). The MR9600-T is the right pick for workflows that need temperature control during the read; the base MR9600 (without incubation) is sufficient for endpoint-only ELISA / immunoassay workflows.

Voltage options: This unit can be ordered with European voltage requirements (230V/50Hz). Contact us to order.

Key Specifications

For complete instrument specifications and wavelength filter family context, see the MR9600 parent page (base chassis without incubation).

SKUMR9600-T
Voltage115 V
Plate format96-well
Wavelength filter family28+ filters spanning 340 nm UV to 750 nm near-IR (same family as base chassis)
Incubation moduleBuilt-in temperature-controlled plate incubation (operator-set temperature; supports 37 °C biological temperature and other temperature ranges per workflow)
List price$7,751

Why Incubation Matters — Kinetic Assays vs Endpoint Assays

Assay typeWorkflowRead patternIncubation requirement
Endpoint ELISA / immunoassayApply samples → wash → develop → read once at signal-development timeSingle absorbance read at endpointNone — base MR9600 is sufficient
Kinetic enzyme assayAdd substrate → measure absorbance change over timeMultiple absorbance reads at fixed time intervalsRequired — temperature drift would distort the rate calculation
Cell-based microplate assayMaintain cells in plate while reading absorbance over timeSingle or multiple reads with cells alive in the plateRequired — cells must be at culture temperature
Receptor-binding kineticAdd ligand → measure binding-rate absorbance changeMultiple reads at fixed intervalsRequired — kinetic-rate measurements are temperature-dependent

Pick the MR9600-T (with incubation) when:

  • The workflow includes kinetic enzyme-rate measurements (e.g., enzyme-substrate Vmax / Km determination)
  • Cell-based microplate assays require live-cell maintenance at culture temperature during the read
  • Time-course absorbance workflows where temperature drift would introduce read-to-read variance
  • Published protocols specifying incubation temperature during the read step

Pick the base MR9600 (no incubation) when:

  • Endpoint-only ELISA / immunoassay workflows
  • Standard absorbance quantification (BCA, Bradford, MTT, OD600) at room temperature
  • Protein quantification workflows that do not require temperature control

MR9600-T vs MR9600 — Pricing Differential

VariantList priceDifferential
MR9600 (base, no incubation)(see MR9600 page for parent pricing)
MR9600-T (this product, with incubation)$7,751Incubation-module premium

The MR9600-T premium reflects the incubation hardware; for endpoint-only workflows, the differential is unnecessary capital spend. For kinetic / cell-based / time-course workflows, the incubation capability is workflow-mandatory and the premium is justified.

Application Profile

Enzyme-kinetics workflows — Vmax / Km determination, enzyme-substrate kinetic-rate measurements, enzyme-inhibitor IC₅₀ determinations.

Cell-based microplate assays — viability assays (MTT, MTS, XTT) that require live-cell maintenance during the read; cell-proliferation assays; cytotoxicity assays.

Receptor-binding kinetic assays — binding-rate measurements for receptor-ligand interaction studies.

Time-course endpoint workflows — workflows where a single absorbance read is taken at a precise temperature-controlled endpoint (vs reading immediately at ambient).

Bacterial-growth kinetic assays — OD600 measurements over time for bacterial-growth-curve studies.

Multi-investigator core facility setup — shared MR9600-T equipment in core facilities supports both endpoint and kinetic workflows on the same chassis (vs maintaining separate base + incubated readers).

Frequently Asked Questions

What does the "-T" add to the MR9600? Built-in temperature-controlled plate incubation, for reads that must be held at a set temperature.

When is the incubation capability needed? For kinetic enzyme assays, cell-based microplate assays, and time-course reads. Endpoint-only ELISA / immunoassay workflows do not require it and can use the base MR9600.

What plate format does it use? 96-well.

What wavelengths are supported? The same 28+ filter family as the base chassis, spanning 340 nm UV to 750 nm near-IR.

How does it differ from the base MR9600? The base MR9600 has no incubation module and suits endpoint-only workflows; the MR9600-T adds incubation for kinetic / cell-based / time-course workflows.

Ordering & Configuration

Workflow-fit decision at quote. Confirm the lab actually needs the incubation capability — endpoint-only ELISA workflows do not benefit from the MR9600-T premium. Step to the base MR9600 if the workflow is endpoint-only.

Wavelength filter inventory. Confirm which workflow wavelengths the lab needs — the MR9600-T uses the same wavelength filter family as the base MR9600 (28+ filters). The chassis ships with one or more filters; additional filters are sold separately (e.g., MR9600-450 for TMB ELISA, MR9600-562 for BCA, MR9600-595 for Bradford, MR9600-600 for OD600, MR9600-663 for chlorophyll, etc.).

Confirm at quote: voltage and plug type (this 115 V SKU vs the 230 V variant), workflow incubation requirements (drives MR9600-T-vs-MR9600 decision), wavelength filter inventory, MW9600 washer pairing, training requirements, and lead time.

Warranty: Per Accuris standard warranty terms — confirm at quote.

Accuris MR9600 SmartReader 96 chassis tier comparison:

- MR9600 — Base chassis, no incubation (endpoint-only ELISA / immunoassay)

- Base chassis, no incubation, 230 V (by special order)

- MR9600-T (this product) — Chassis with incubation, 115 V ($7,751)

- Chassis with incubation, 230 V (by special order, $7,751)

Pick the incubation variant for kinetic / cell-based / time-course workflows; pick the base chassis for endpoint-only workflows.

🎬

See It In Action

Manufacturer video for MR9600-T
BenchmarkScientificYouTube

Authorized Distributor

Genuine, factory-warrantied units

🚚

Ships from USA

Fast domestic delivery

💬

Expert Support

Real specialists, fast response

💰

Competitive Pricing

Authorized-partner pricing

Frequently Asked Questions

Why Legacy Lab Supplies?

🏆

Authorized Dealer

We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.

💡

Expert Guidance

Not sure which model fits your lab? Our team speaks your language — we help you spec the right equipment for your exact application and budget.

📋

Procurement Made Easy

PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.

💰

Competitive Pricing

Competitive pricing every day — and we'll match any legitimate competitor price. You get premium equipment without the premium markup.

🚚

Reliable Fulfillment

Direct to your dock. You get the latest stock straight from the source — and if we don't have inventory, we work with the manufacturer to get what you need.

🤝

Long-Term Partner

Legacy Lab Supplies isn't just a transaction. We're building a long-term relationship with every lab we serve — from first quote to repeat orders.

📁 Product Documents

Common Questions

How much does the SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V cost?+

The SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V (MR9600-T) is $7,750.68 at Legacy Lab Supplies, with transparent pricing shown up front — no login or quote required.

Does the SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V come with a manufacturer warranty?+

Yes. Legacy Lab Supplies is an authorized Accuris distributor, so every SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V ships new with the full Accuris factory warranty.

What are the key specifications of the SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V?+

Key specifications of the SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V: Class: Capital — microplate absorbance reader with incubation; Voltage: 115 V; Plate format: 96-well; Incubation module: Built-in temperature-controlled plate incubation (operator-set temperature; supports 37 °C biological temperature and other temperature ranges per workflow). The complete manufacturer specification table is on this page.

How does the SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V ship?+

The SmartReader 96 Microplate Absorbance Reader with Incubation , 115 V ships by standard parcel carrier. Current lead time: Unknown.

My Cart

🛒

Your Cart is empty

Browse Products