Calibration Plate for MR9600 SmartReader™ 96
Volume Pricing
Sign in and place an order to unlock bulk pricing.
Auto-Reorder
Unlocks with a Credit account. Contact us to apply.
Bundle & Save
Unlocks with a Credit account. Contact us to apply.

Volume Pricing
Sign in and place an order to unlock bulk pricing.
Auto-Reorder
Unlocks with a Credit account. Contact us to apply.
Bundle & Save
Unlocks with a Credit account. Contact us to apply.
The MR9600-CAL is the dedicated calibration plate for the Accuris MR9600 SmartReader 96 Microplate Absorbance Reader — a precision-manufactured plate with NIST-traceable absorbance standards used to verify and calibrate the chassis's absorbance accuracy across its wavelength and OD range. Calibration plates are workflow-recurring instrument-QC accessories that institutional labs use on a periodic schedule (typically quarterly or per-protocol) to confirm the instrument's measurement accuracy and detect any drift requiring service intervention.
Author confidence note (MEDIUM): Brochure context for MR9600-CAL specifically is sparse in the available Accuris catalog corpus. The product description below is inferred from standard microplate-reader calibration-plate conventions (NIST-traceable absorbance standards, periodic calibration workflow, paired with chassis-specific software calibration routine). Confirm at first order: specific NIST traceability documentation, calibration wavelengths covered, recertification interval, and software-integration workflow.
| SKU | MR9600-CAL |
| Type | Calibration plate — for MR9600 SmartReader 96 microplate absorbance reader |
| Function | Verify and calibrate chassis absorbance accuracy across wavelength and OD range |
| Standard traceability | NIST-traceable absorbance standards (per standard microplate-reader calibration-plate convention; confirm at order) |
| Compatible chassis | MR9600 SmartReader 96 microplate absorbance reader |
| Workflow position | Periodic instrument-QC accessory — typical use on quarterly or per-protocol basis |
Microplate-reader calibration plates are precision-manufactured glass or polymer plates containing NIST-traceable optical-density standards in defined positions. The standards are characterized at known absorbance values across the chassis's measurement wavelength range; running the calibration plate through the chassis's software-driven calibration routine compares the chassis's measured absorbance against the certified standard absorbance to:
Plate pairing — MR9600 SmartReader 96 only. Order this SKU when:
Institutional clinical-research and clinical labs — operations under FDA 21 CFR Part 11, ISO 17025, GLP, or similar QM frameworks where microplate-reader periodic calibration is part of the audit-trail requirement.
Hospital reference labs — clinical chemistry and immunoassay labs where MR9600 absorbance accuracy directly affects patient-result quality.
Pharma R&D and bioprocess QC labs — drug-discovery primary-screen and bioprocess-QC workflows where instrument calibration is part of the QM workflow.
Academic core facilities — shared microplate-reader instruments where periodic calibration documentation supports user-charge billing and QM reporting.
Service-contract supplementation — labs that maintain MR9600 service contracts often supplement contract calibration with operator-driven periodic calibration using this plate.
Calibration workflow. Per standard microplate-reader calibration convention: insert the calibration plate into the MR9600, run the chassis's calibration software routine, review the calibration report against the manufacturer accuracy spec, document the result in the institutional QM log, and store the plate per the manufacturer's storage instructions until the next calibration cycle.
Plate storage and lifetime. Calibration plates have a finite shelf life — typically protected from light exposure and temperature-controlled storage between use. The recertification interval (typically 1-2 years per standard convention) defines when the plate must be replaced; confirm with Accuris at first order.
Confirm at quote: chassis pairing (MR9600 in inventory), specific NIST traceability documentation needs, recertification interval, calibration software workflow integration, institutional QM framework requirements (FDA 21 CFR Part 11, ISO, GLP), and lead time.
Warranty: Per Accuris standard warranty terms for calibration accessories — confirm at quote.
MR9600 SmartReader 96 accessory family:
- MR9600-CAL (this product) — Calibration plate for periodic instrument QC
- MR9610-CAL — Calibration plate for MR9610 / MR9611 (different chassis)
- MR9610-SDP — SmartDrop Accessory Plate for MR9610
- MR9620-CFR — SmartReader PC Security Software (FDA 21 CFR Part 11)
Pick the MR9600-CAL when the workflow includes periodic calibration of the MR9600 SmartReader 96 chassis specifically; for MR9610 / MR9611 chassis, use the MR9610-CAL instead.
Authorized Distributor
Genuine, factory-warrantied units
Ships from USA
Fast domestic delivery
Expert Support
Real specialists, fast response
Competitive Pricing
Authorized-partner pricing
We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.
Not sure which model fits your lab? Our team speaks your language — we help you spec the right equipment for your exact application and budget.
PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.
Competitive pricing every day — and we'll match any legitimate competitor price. You get premium equipment without the premium markup.
Direct to your dock. You get the latest stock straight from the source — and if we don't have inventory, we work with the manufacturer to get what you need.