The Accuris One-Step RT-PCR Kit is a single-tube cDNA synthesis + PCR amplification kit for RNA → DNA → amplification workflows. The PR1100-50 is the 50-reaction pack — supports a meaningful validation or routine workflow batch. Per the Accuris Life Science Reagents Catalog: *"Convenient cDNA synthesis and subsequent PCR in a single tube."* The kit's chemistry is optimized for low-copy transcripts — the workflow is sensitive enough to detect dilute mRNA inputs without separate cDNA synthesis + PCR setup steps. Hot Start Taq Polymerase is included to prevent the non-specific amplification that two-step RT-PCR workflows typically suffer from at the PCR-setup transition.
| SKU | PR1100-50 |
| Type | Single-tube One-Step RT-PCR kit |
| Pack quantity | 50 reactions |
| Starting material | RNA |
| Workflow | cDNA synthesis (RT step) → PCR amplification (PCR step) in single tube — no transfer between steps |
| Sensitivity | Optimized chemistry for low-copy transcript detection |
| Kit contents | 1 tube of 20X thermostable RTase (RNase inhibitor included) + 1 tube of 2X One-Step Mix (PCR enhancers, 2 mM dNTPs, 6 mM MgCl₂) |
| Hot Start chemistry | Hot Start Taq Polymerase included — prevents nonspecific amplification at the RT-to-PCR transition |
| RNase inhibitor | Included in the 20X RTase tube — protects RNA from nuclease degradation during the RT step |
| Sister SKUs | PR1100-100 (100 reactions, $549), PR1100-S (sample, 10 reactions, $65) |
| List price | $304 |
Traditional two-step RT-PCR workflow:
One-step workflow (this kit) collapses all three into one tube: all reagents — RTase, Hot Start Taq, RNase inhibitor, buffer, dNTPs, primers, and RNA — are combined upfront, and the thermal cycler protocol drives both steps (an initial RT-temperature incubation for cDNA synthesis, then standard PCR cycling once the Hot Start activates the Taq). Because there is no tube transfer, the workflow eliminates the contamination, loss, and pipetting-error risk of the inter-step transfer.
Workflow advantages of one-step:
Hot Start Taq inclusion is critical for one-step success — without hot-start chemistry, the Taq would be active during the RT-temperature incubation and would generate non-specific PCR products from the as-synthesized cDNA before the formal PCR cycling begins.
| SKU | Reactions | List price | Per-reaction cost |
| PR1100-S | 10 | $65 | $6.50 |
| PR1100-50 (this product) | 50 | $304 | $6.08 |
| PR1100-100 | 100 | $549 | $5.49 |
Pick the PR1100-50 when: workflow throughput is moderate — typical clinical-research RT-PCR workflow consuming 50 reactions across a few weeks of project work, gene-expression studies running 50-sample panels, or method-development workflows beyond the 10-reaction sample scope. Step up to PR1100-100 for 100+ reactions per quarter; step down to PR1100-S for protocol validation.
Per the Accuris Life Science Reagents Catalog, One-Step RT-PCR Kit applications include multiplex RT-PCR (multiple primer pairs in one tube for multi-target gene-expression analysis) and gene-expression analysis (quantitative or semi-quantitative mRNA measurement at endpoint-RT-PCR scope; for fluorescence-based real-time RT-qPCR, see the qMAX RT-qPCR family).
Typical application contexts include pathogen detection (viral RNA detection, research-use only per kit positioning), gene-expression studies comparing target-gene mRNA levels across treatment and control conditions, mRNA-target validation confirming target presence in tissue or cell-line samples, and method-development RT-PCR for downstream qPCR assay design.
Routine gene expression analysis — the workhorse application. Endpoint RT-PCR for mRNA detection / semi-quantitative analysis.
Multiplex RT-PCR panels — multi-target gene expression measurement on a single sample input.
Pathogen RNA detection (research-use only) — viral RNA detection workflows in research labs.
Clinical-research mRNA workflows — clinical-research labs running RT-PCR for biomarker discovery or validation studies.
Method-development for downstream qPCR — protocol-development RT-PCR workflows that validate primer design before stepping to qMAX qPCR fluorescence chemistry.
Educational laboratory RT-PCR exercises — molecular-biology coursework introducing RT-PCR workflow.
Per-reaction workflow consumable. Each One-Step RT-PCR reaction consumes proportional reagent from the included tubes. The 50-reaction pack supports 50 RT-PCR reactions before reorder.
Storage. RT-PCR reagent storage applies — typically -20 °C; thermostable RTase storage protocol per product insert. RNase-free handling required throughout.
Pair with RNA template + sequence-specific primers. The kit includes the polymerase + RT + buffer + dNTPs + RNase inhibitor; operator supplies the RNA template and the gene-specific PCR primers (for one-step RT-PCR, the same primer pair drives both the RT step and the PCR step — no separate random hexamer / oligo-dT priming).
Confirm at quote: workflow throughput (drives 50-rxn vs 100-rxn pack-size selection), evaluation interest (PR1100-S sample at $65 for first-use validation), workflow application (gene expression vs pathogen detection vs method-development), and lead time.
Warranty: Per Accuris standard reagent terms — confirm at quote.
Accuris PR1100 One-Step RT-PCR kit family:
- PR1100-S — Sample, 10 reactions ($65)
- PR1100-50 (this product) — One-Step RT-PCR Kit, 50 reactions ($304)
- PR1100-100 — One-Step RT-PCR Kit, 100 reactions ($549)
Pick the 50-reaction pack for moderate-throughput RT-PCR workflows; step to 100-rxn for higher throughput or sample for protocol validation.
Authorized Distributor
Genuine, factory-warrantied units
Ships from USA
Fast domestic delivery
Expert Support
Real specialists, fast response
Competitive Pricing
Authorized-partner pricing
We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.
Not sure which model fits your lab? Our team speaks your language — we help you spec the right equipment for your exact application and budget.
PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.
Competitive pricing every day — and we'll match any legitimate competitor price. You get premium equipment without the premium markup.
Direct to your dock. You get the latest stock straight from the source — and if we don't have inventory, we work with the manufacturer to get what you need.
Legacy Lab Supplies isn't just a transaction. We're building a long-term relationship with every lab we serve — from first quote to repeat orders.