The AP1024-DWP is the 14.6 mL deep-well plate consumable for the Accuris AP1024 IsoPure 24 Automated Purification System — sold as pack of 24 plates per the 2026 universe price-list. The deep-well plate is the per-cycle sample vessel for IsoPure 24 magnetic-bead extraction workflows; the 14.6 mL well volume supports the IsoPure 24's wider sample-volume range (50 µL to 10,000 µL per the chassis brochure) — substantially larger than the IsoPure Mini's 50–1,000 µL range.
Pack-size discrepancy note (FQ-013 candidate): The AP1024 brochure's ordering table lists *"AP1024-DWP — 24 deep well plates for IsoPure, pack of 50"* — but the 2026 universe price-list label specifies pack of 24. This page is authored to the universe spec (pack of 24); the discrepancy may reflect catalog evolution between the brochure issue date and the 2026 price-list update. Confirm pack quantity at quote with Accuris.
Key Specifications
| SKU | AP1024-DWP |
| Type | Deep-well plate for IsoPure 24 magnetic-bead extraction |
| Pack quantity | 24 plates per pack (per 2026 universe price-list — see discrepancy note above) |
| Per-well volume | 14.6 mL (supports up to 10,000 µL sample volume per IsoPure 24 chassis specification) |
| Compatible chassis | AP1024 IsoPure 24 |
| Workflow scale | Up to 24 samples per IsoPure 24 cycle (high-throughput plate format) |
| Sample volume range | 50 µL – 10,000 µL per chassis specification |
Compatibility & When to Order This SKU
Deep-well plate consumable — IsoPure 24 chassis only. Order this SKU when:
- Initial chassis commissioning — order an initial supply of plates when commissioning a new AP1024 chassis to support workflow startup.
- Workflow-recurring replenishment — magnetic-bead purification consumes one deep-well plate per protocol run; replenishment cadence depends on workflow throughput.
- High-volume sample workflows — workflows where samples exceed 1,000 µL volume require the IsoPure 24's wider 50–10,000 µL range and the 14.6 mL deep-well plate format (the IsoPure Mini's 96 deep-well plate format is volume-limited to 1,000 µL).
- Multi-chassis facility consumable inventory — facilities running multiple IsoPure 24 chassis maintain centralized deep-well plate inventory.
IsoPure 24 vs IsoPure Mini Sample-Vessel Volume Range
| Chassis | Sample volume range | Sample-vessel format | Per-cycle samples |
| AP1016 IsoPure Mini | 50 µL – 1,000 µL | 6-well strip + aluminum rack OR 96 deep-well plate | 1–16 |
| AP1024 IsoPure 24 (pairs with this plate) | 50 µL – 10,000 µL | 14.6 mL deep-well plate (this SKU) | Up to 24 |
The IsoPure 24's 10× wider volume range (10,000 µL vs 1,000 µL) is a primary chassis differentiator — workflows requiring large sample volumes (e.g., bulk-sample extractions for downstream sequencing, large-volume environmental samples, high-input clinical samples) require the IsoPure 24 chassis and the 14.6 mL deep-well plate format. The IsoPure Mini's smaller plate format does not support these volumes.
Design Architecture
Per-cycle plate consumable. Each IsoPure 24 extraction cycle uses one deep-well plate. The plate is loaded into the chassis processing chamber, the protocol runs (with the chassis's 8-position carousel + 2 heating blocks engaging the plate per protocol step), and the plate is discarded at cycle end.
Tip-comb pairing. The AP1024 workflow pairs the deep-well plate with the AP1024-TC 24-place tip comb (sold separately, pack of 50 per brochure). One tip comb per cycle, alongside one deep-well plate.
Magnetic-assembly compatibility. The IsoPure 24 chassis includes a 24-place magnetic assembly engineered for the deep-well plate format — bead-transfer geometry is plate-format-specific.
Application Profile
High-volume nucleic-acid extraction — workflows with input sample volumes 1,000 µL to 10,000 µL where the IsoPure Mini's volume range is insufficient.
NGS library prep — high-input library preparation workflows where larger sample volumes feed into downstream library construction.
Environmental and microbiome samples — environmental DNA / microbiome extractions with large input volumes (water, soil suspension, lavage samples).
Clinical large-volume sample extraction — clinical research workflows with whole-blood or plasma extraction volumes exceeding the IsoPure Mini's range.
Bulk-protein extraction — protein purification workflows with large lysate volumes feeding into downstream characterization.
Ordering & Configuration
Per-cycle workflow consumable. Each IsoPure 24 extraction cycle uses one deep-well plate. Plan procurement to match the workflow's per-month or per-quarter cycle count.
Pair with AP1024-TC tip comb. Both consumables are required per cycle; confirm both inventories at order.
Confirm at quote: chassis pairing (AP1024 in inventory), workflow throughput (per-month extraction cycle count), pack-size confirmation (24 vs 50 per FQ-013 query), tip-comb inventory (AP1024-TC), and lead time.
Warranty: Per Accuris standard consumable terms — confirm at quote.
Accuris IsoPure 24 per-cycle consumable family:
- AP1024-DWP (this product) — 14.6 mL deep-well plate, 24/pack (per-cycle sample vessel)
- AP1024-TC — 24-place tip comb, pack of 50 (per-cycle bead-transfer comb)
The deep-well plate + tip comb combination is workflow-mandatory for every IsoPure 24 extraction cycle.