The AP1096-DWP is the 96-well deep-well plate consumable for the Accuris AP1096 IsoPure 96 Automated Purification System — sold as case of 50 plates. The deep-well plate is the per-cycle sample vessel for IsoPure 96 high-throughput magnetic-bead extraction workflows; the chassis processes up to 96 samples per cycle in this plate format. Per the IsoPure 96 brochure, the deep-well plate is engineered to fit into the chassis's 2 heating blocks for efficient heat transfer during the lysis and elution protocol steps.
Key Specifications
| SKU | AP1096-DWP |
| Type | 96-well deep-well plate for IsoPure 96 magnetic-bead extraction |
| Pack quantity | Case of 50 plates |
| Wells per plate | 96 (full 8 × 12 plate footprint) |
| Compatible chassis | AP1096 IsoPure 96 |
| Sample volume range | 50 µL – 1,000 µL per chassis specification |
| Heating-block compatibility | Plate fits into chassis 2 heating blocks per brochure for efficient heat transfer (ambient +5 °C to 120 °C operating range) |
| Workflow scale | Up to 96 samples per cycle |
| List price | $274 (case of 50) |
Compatibility & When to Order This SKU
Deep-well plate consumable — IsoPure 96 chassis only. Order this SKU when:
- Initial chassis commissioning — order an initial supply of plates (case of 50 minimum) when commissioning a new AP1096 chassis to support workflow startup.
- Workflow-recurring replenishment — magnetic-bead purification consumes one deep-well plate per protocol run; replenishment cadence depends on workflow throughput.
- High-throughput facility consumable inventory — production / clinical-research labs running daily 96-sample IsoPure 96 batches consume plates at ~5 cases / month or more depending on throughput.
- Multi-chassis facilities — facilities running multiple IsoPure 96 chassis maintain centralized plate inventory.
IsoPure 96 vs IsoPure 24 vs IsoPure Mini Sample-Vessel Format Comparison
| Chassis | Per-cycle samples | Sample volume range | Plate format SKU |
| AP1016 IsoPure Mini | 1–16 | 50 µL – 1,000 µL | AP1016-6W (strips) or 96 deep-well |
| AP1024 IsoPure 24 | Up to 24 | 50 µL – 10,000 µL | AP1024-DWP (14.6 mL deep-well) |
| AP1096 IsoPure 96 (pairs with this plate) | Up to 96 | 50 µL – 1,000 µL | AP1096-DWP (96-well deep-well) — this SKU |
The IsoPure 96's 96-sample throughput is the chassis differentiator vs the smaller IsoPure 24 (24 samples) and IsoPure Mini (1–16 samples) — workflows requiring high sample-batch throughput at standard volume range (50–1,000 µL) target the AP1096 platform with this deep-well plate.
Design Architecture
Per-cycle plate consumable. Each IsoPure 96 extraction cycle uses one deep-well plate. The plate is loaded into the chassis processing chamber at one of the 8 plate positions, the protocol runs (with the chassis's 8-position carousel + 2 heating blocks engaging the plates per protocol step), and the plate is discarded at cycle end.
Heating-block thermal coupling. Per IsoPure 96 brochure: *"Heating of the sample mixture during the lysis and elution steps significantly improves the purity and yield of the target molecule. The IsoPure 96 is equipped with 2 heating blocks on the plate carousel that can be precisely set to temperatures from ambient + 5°C to 120°C. IsoPure deep well plates fit into the heating blocks for efficient heat transfer."* The AP1096-DWP plate is engineered for this heating-block fit.
Multi-step protocol layout. The IsoPure 96 protocol typically uses one or more deep-well plates per cycle to support the multi-step magnetic-bead workflow (lysis → binding → wash → elution). Workflows requiring elution into a different plate format use the AP1096-ELP elution plate (96-well elution plates, sold separately at $523 / case of 100).
Tip-comb pairing. Each cycle also requires the AP1096-TC tip comb (sold separately, case of 50). Both consumables are workflow-mandatory.
Application Profile
High-throughput DNA / RNA / protein extraction — sequencing cores, biotech R&D, clinical-research diagnostics, and other workflows running 96-sample extraction batches.
NGS library prep at scale — sequencing facilities running 96-sample-per-batch library preparation workflows.
Clinical-research diagnostics — clinical research workflows running batch patient-sample extractions.
Pharma / biotech high-throughput screening prep — sample-preparation workflows feeding downstream high-throughput screening.
Method-development on production-scale platform — protocol validation on the IsoPure 96 chassis where the smaller-chassis validation is insufficient.
Ordering & Configuration
Per-cycle workflow consumable. Each IsoPure 96 extraction cycle uses one deep-well plate. Plan procurement to match the workflow's per-month or per-quarter cycle count.
Pair with AP1096-TC tip comb. Both consumables are required per cycle; confirm both inventories at order. Optionally pair with AP1096-ELP elution plate if the workflow uses a separate elution plate format.
Confirm at quote: chassis pairing (AP1096 in inventory), workflow throughput (per-month extraction cycle count), tip-comb inventory (AP1096-TC), elution-plate inventory (AP1096-ELP if applicable), and lead time.
Warranty: Per Accuris standard consumable terms — confirm at quote.
Accuris IsoPure 96 per-cycle consumable family:
- AP1096-DWP (this product) — 96 deep-well plates, case of 50 (per-cycle sample vessel)
- AP1096-TC — Tip Comb, case of 50 (per-cycle bead-transfer comb)
- AP1096-ELP — 96-well elution plates, case of 100 (optional separate-elution-plate workflow)
Deep-well plate + tip comb is the workflow-mandatory consumable pair for every IsoPure 96 extraction cycle.