Legacy Lab SuppliesPO
๐Ÿ”
Automatic Nucleic Acid Extraction System , 96-Sample Throughput - Automated Nucleic Acid Extraction | Legacy Lab Supplies

Automatic Nucleic Acid Extraction System , 96-Sample Throughput

$59,500.00$70,000.00Sale
๐Ÿ’ฐ You save $10,500.00 vs MSRP
The Yamato VNP-96P is a high-throughput automated nucleic-acid extractor that purifies DNA and RNA from up to 96 samples per run using magnetic-bead chemistry.
1

Lead Time

6โ€“10 Weeks

Delivery

Freight / White Glove

Warranty

Full Manufacturer Warranty Support

๐Ÿ”’

Authorization Hold โ€” Not Charged Immediately

Your card is authorized at checkout. Final charge confirmed after shipping is arranged.

Download Quick View
SKU: VNP-96P

Looking at other brands too?

Compare this class of equipment spec-by-spec across our brands โ€” same size, different manufacturer, honest guidance on which fits your application.

Compare Across Brands โ†’

The Yamato VNP-96P is a high-throughput automated nucleic-acid extractor that purifies DNA and RNA from up to 96 samples per run using magnetic-bead chemistry. Paired with prepackaged reagents built on silica-coated superparamagnetic beads, its magnetic rods capture, transfer, and release bead-bound sample through every wash and elution, delivering rapid, consistent purification across blood, tissue, cells, body fluids, bacteria, and viruses. For labs feeding molecular diagnostics or sequencing pipelines, it turns extraction from a bottleneck into an unattended, plate-scale step.

Key Specifications

SKUVNP-96P
ProductAutomatic Nucleic Acid Extraction System
ThroughputUp to 96 samples per run
ChemistryMagnetic-bead purification (silica-coated superparamagnetic beads)
MechanismMagnetic rods capture, transfer, and release beads
ReagentsPrepackaged extraction reagent kits
Sample typesBlood, tissue, cells, body fluids, bacteria, viruses
WorkflowHighly automated, fast, one-step operation
Typical useMolecular diagnosis, research, animal-disease detection

Application Profile

Purity and yield of extracted nucleic acid set the ceiling on every downstream result โ€” a marginal prep degrades qPCR sensitivity and wastes sequencing reads. Automating extraction at 96-sample scale removes the two biggest failure modes of manual prep: operator-to-operator variability and the sheer time cost of high sample counts. In the VNP-96P, nucleic acids bind the silica-coated bead surface, the magnetic rods shuttle the beads through wash buffers, and a clean elution delivers amplification-ready DNA/RNA.

The 96-position format targets high-throughput environments โ€” clinical molecular labs, screening cores, and surveillance programs running full plates on a routine cadence. Bead chemistry keeps the platform matrix-flexible, so the same run recipe accommodates whole blood, tissue lysates, cultured cells, and pathogen samples, with built-in contamination controls protecting cross-well integrity. The payoff is reproducible recovery at plate scale with minimal hands-on time.

Frequently Asked Questions

How many samples can the VNP-96P process per run? Up to 96 samples in a single automated run โ€” full-plate throughput.

What extraction chemistry does it use? Magnetic-bead purification on silica-coated superparamagnetic beads with prepackaged reagents; magnetic rods move the beads through binding, washing, and elution.

What sample types can it handle? Blood, tissue, cells, body fluids, bacteria, and viruses โ€” the bead workflow is tolerant of diverse matrices.

How much hands-on time is involved? It is a highly automated, one-step workflow โ€” load samples and reagents, start, and walk away while the instrument runs unattended.

What applications is it suited to? Molecular diagnosis, research, and animal-disease detection where high-throughput, consistent DNA/RNA recovery is needed upstream of qPCR or NGS.

How does it differ from the VNP-32P? Identical chemistry and workflow; the VNP-96P processes 96 samples per run, while the VNP-32P runs 32 for mid-volume labs.

Ordering & Configuration

Confirm at quote: reagent-kit selection, daily/weekly throughput targets, and integration with downstream qPCR or sequencing.

Warranty: Per Yamato standard capital-equipment terms โ€” confirm coverage at quote.

Add to a quote to lock configuration, reagent kits, and lead time.

Nucleic-acid extraction pair:

- VNP-96P (this product) โ€” 96 samples/run for high-throughput cores and screening.

- VNP-32P โ€” 32 samples/run for steady mid-volume batches.

Choose the VNP-96P when sustained full-plate throughput drives the lab; step down to the VNP-32P when batches are moderate and footprint or budget is the priority.

โœ…

Authorized Distributor

Genuine, factory-warrantied units

๐Ÿšš

Ships from USA

Fast domestic delivery

๐Ÿ’ฌ

Expert Support

Real specialists, fast response

๐Ÿ’ฐ

Competitive Pricing

Authorized-partner pricing

Frequently Asked Questions

Why Legacy Lab Supplies?

๐Ÿ†

Authorized Dealer

We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.

๐Ÿ’ก

Expert Guidance

Not sure which model fits your lab? Our team speaks your language โ€” we help you spec the right equipment for your exact application and budget.

๐Ÿ“‹

Procurement Made Easy

PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.

๐Ÿ’ฐ

Competitive Pricing

Competitive pricing every day โ€” and we'll match any legitimate competitor price. You get premium equipment without the premium markup.

๐Ÿšš

Reliable Fulfillment

Direct to your dock. You get the latest stock straight from the source โ€” and if we don't have inventory, we work with the manufacturer to get what you need.

๐Ÿค

Long-Term Partner

Legacy Lab Supplies isn't just a transaction. We're building a long-term relationship with every lab we serve โ€” from first quote to repeat orders.

๐Ÿ“ Product Documents

Common Questions

How much does the Automatic Nucleic Acid Extraction System , 96-Sample Throughput cost?+

The Automatic Nucleic Acid Extraction System , 96-Sample Throughput (VNP-96P) is $70,000.00 at Legacy Lab Supplies, with transparent pricing shown up front โ€” no login or quote required.

Does the Automatic Nucleic Acid Extraction System , 96-Sample Throughput come with a manufacturer warranty?+

Yes. Legacy Lab Supplies is an authorized Yamato distributor, so every Automatic Nucleic Acid Extraction System , 96-Sample Throughput ships new with the full Yamato factory warranty.

What are the key specifications of the Automatic Nucleic Acid Extraction System , 96-Sample Throughput?+

Key specifications of the Automatic Nucleic Acid Extraction System , 96-Sample Throughput: Class: Capital โ€” automated instrument; Product: Automatic Nucleic Acid Extraction System; Reagents: Prepackaged extraction reagent kits; Workflow: Highly automated, fast, one-step operation. The complete manufacturer specification table is on this page.

How does the Automatic Nucleic Acid Extraction System , 96-Sample Throughput ship?+

The Automatic Nucleic Acid Extraction System , 96-Sample Throughput ships by freight carrier on a pallet. Liftgate and white-glove delivery options are available, and freight cost is confirmed on your quote or at checkout. Current lead time: Unknown.

My Cart

๐Ÿ›’

Your Cart is empty

Browse Products