Legacy Lab SuppliesPO
🔍
Automatic Nucleic Acid Extraction System , 32-Sample Throughput - Automated Nucleic Acid Extraction | Legacy Lab Supplies

Automatic Nucleic Acid Extraction System , 32-Sample Throughput

$21,675.00$25,500.00Sale
💰 You save $3,825.00 vs MSRP
The Yamato VNP-32P is a high-precision automated nucleic-acid extractor that purifies DNA and RNA from up to 32 samples per run using magnetic-bead chemistry.
1

Lead Time

6–10 Weeks

Delivery

Freight / White Glove

Warranty

Full Manufacturer Warranty Support

🔒

Authorization Hold — Not Charged Immediately

Your card is authorized at checkout. Final charge confirmed after shipping is arranged.

Download Quick View
SKU: VNP-32P

Looking at other brands too?

Compare this class of equipment spec-by-spec across our brands — same size, different manufacturer, honest guidance on which fits your application.

Compare Across Brands →

The Yamato VNP-32P is a high-precision automated nucleic-acid extractor that purifies DNA and RNA from up to 32 samples per run using magnetic-bead chemistry. It runs with prepackaged extraction reagents built on silica-coated superparamagnetic beads, and a set of magnetic rods captures, transfers, and releases those beads through each wash and elution step. The result is a fast, simple, one-step workflow that pulls clean nucleic acid from blood, tissue, cells, body fluids, bacteria, and viruses with minimal hands-on time.

Key Specifications

SKUVNP-32P
ProductAutomatic Nucleic Acid Extraction System
ThroughputUp to 32 samples per run
ChemistryMagnetic-bead purification (silica-coated superparamagnetic beads)
MechanismMagnetic rods capture, transfer, and release beads
ReagentsPrepackaged extraction reagent kits
Sample typesBlood, tissue, cells, body fluids, bacteria, viruses
WorkflowHighly automated, fast, one-step operation
Typical useMolecular diagnosis, research, animal-disease detection

Application Profile

Nucleic-acid extraction is the gate every downstream molecular assay passes through — qPCR, sequencing, and genotyping all fail or succeed on the purity and yield of the input DNA/RNA. Manual column preps are slow and hard to reproduce across operators; magnetic-bead automation solves both. In the VNP-32P, nucleic acids bind the silica surface of the beads under a chaotropic buffer, the magnetic rods carry the bead-bound sample through wash steps, and a low-salt elution releases purified nucleic acid ready for amplification.

The 32-position format suits labs with steady mid-volume batches — clinical molecular diagnostics, research cores, and veterinary/animal-disease surveillance. Because the chemistry is bead-based rather than column-based, the same instrument handles a wide range of sample matrices, from whole blood to bacterial and viral lysates, with contamination-control features that protect run-to-run integrity. The one-step, walk-away operation is where the automation pays back: consistent recovery without the pipetting burden of a spin-column protocol.

Frequently Asked Questions

How many samples can the VNP-32P process per run? Up to 32 samples in a single automated run.

What extraction chemistry does it use? Magnetic-bead purification on silica-coated superparamagnetic beads, driven by prepackaged reagent kits. Magnetic rods move the beads through binding, washing, and elution.

What sample types can it handle? Blood, tissue, cells, body fluids, bacteria, and viruses — a broad range because bead chemistry is matrix-tolerant.

How much hands-on time does it require? It is a highly automated, one-step workflow: load samples and reagent cartridges, start the run, and walk away.

What is it used for? Molecular diagnosis, general research, and animal-disease detection where consistent DNA/RNA recovery feeds downstream qPCR or sequencing.

How does it differ from the VNP-96P? Same chemistry and workflow; the VNP-32P runs 32 samples per batch, while the VNP-96P scales to 96 samples for higher-throughput labs.

Ordering & Configuration

Confirm at quote: reagent-kit selection for your sample types, expected batch sizes, and integration with downstream qPCR or sequencing workflows.

Warranty: Per Yamato standard capital-equipment terms — confirm coverage at quote.

Add to a quote to lock configuration, reagent kits, and lead time.

Nucleic-acid extraction pair:

- VNP-32P (this product) — 32 samples/run for steady mid-volume batches.

- VNP-96P — 96 samples/run for high-throughput cores and screening.

Choose the VNP-32P when batch sizes are moderate and bench footprint or budget matters; step up to the VNP-96P when sustained 96-sample throughput is the constraint.

Authorized Distributor

Genuine, factory-warrantied units

🚚

Ships from USA

Fast domestic delivery

💬

Expert Support

Real specialists, fast response

💰

Competitive Pricing

Authorized-partner pricing

Frequently Asked Questions

Why Legacy Lab Supplies?

🏆

Authorized Dealer

We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.

💡

Expert Guidance

Not sure which model fits your lab? Our team speaks your language — we help you spec the right equipment for your exact application and budget.

📋

Procurement Made Easy

PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.

💰

Competitive Pricing

Competitive pricing every day — and we'll match any legitimate competitor price. You get premium equipment without the premium markup.

🚚

Reliable Fulfillment

Direct to your dock. You get the latest stock straight from the source — and if we don't have inventory, we work with the manufacturer to get what you need.

🤝

Long-Term Partner

Legacy Lab Supplies isn't just a transaction. We're building a long-term relationship with every lab we serve — from first quote to repeat orders.

📁 Product Documents

Common Questions

How much does the Automatic Nucleic Acid Extraction System , 32-Sample Throughput cost?+

The Automatic Nucleic Acid Extraction System , 32-Sample Throughput (VNP-32P) is $25,500.00 at Legacy Lab Supplies, with transparent pricing shown up front — no login or quote required.

Does the Automatic Nucleic Acid Extraction System , 32-Sample Throughput come with a manufacturer warranty?+

Yes. Legacy Lab Supplies is an authorized Yamato distributor, so every Automatic Nucleic Acid Extraction System , 32-Sample Throughput ships new with the full Yamato factory warranty.

What are the key specifications of the Automatic Nucleic Acid Extraction System , 32-Sample Throughput?+

Key specifications of the Automatic Nucleic Acid Extraction System , 32-Sample Throughput: Class: Capital — automated instrument; Product: Automatic Nucleic Acid Extraction System; Reagents: Prepackaged extraction reagent kits; Workflow: Highly automated, fast, one-step operation. The complete manufacturer specification table is on this page.

How does the Automatic Nucleic Acid Extraction System , 32-Sample Throughput ship?+

The Automatic Nucleic Acid Extraction System , 32-Sample Throughput ships by freight carrier on a pallet. Liftgate and white-glove delivery options are available, and freight cost is confirmed on your quote or at checkout. Current lead time: Unknown.

My Cart

🛒

Your Cart is empty

Browse Products