The PR2124-N-100 is the No ROX formulation of the Accuris qMAX Probe One-Step 4× Multiplex RT-qPCR Kit — sold as 100-reaction entry pack. The highest-multiplex variant in the qMAX RT-qPCR family — engineered for 4-target multiplex (vs PR2122's 2–3 target capacity), supporting 4-fluorophore-channel detection in a single reaction. Same probe-based hydrolysis-probe / molecular-beacon detection chemistry as the PR2121 single-target and PR2122 2–3 target multiplex sister chemistries, but with master-mix formulation engineered for the higher-target-count multiplex efficiency requirements.
Key Specifications
| SKU | PR2124-N-100 |
| Type | One-Step 4× Multiplex RT-qPCR Kit — qMAX Probe 4× Multiplex No ROX |
| Pack quantity | 100 reactions |
| Multiplex capacity | 4 targets per reaction |
| Detection chemistry | Multi-target probe-based — 4 fluorophore-labeled probes per reaction |
| ROX level | No ROX — Bio-Rad CFX, Roche, Stratagene Mx, Eppendorf, Qiagen |
| Cycler requirement | 4-fluorophore-channel cycler (typical Bio-Rad CFX96 or higher; ABI 7500 / QuantStudio Standard configurations also support 4-channel) |
| Per-reaction cost | $1.96 per reaction (same as PR2122 2–3 target multiplex — 4× chemistry carries no additional premium over 2–3× multiplex) |
| Sister chemistries | PR2121 (single-target), PR2122 (2–3 target multiplex) |
| Sister pack sizes | PR2124-N-S (sample), PR2124-N-500 ($854), PR2124-N-1000 (already authored), PR2124-N-2000 / -100BLK / -50BLK (already authored bulk variants) |
| List price | $196 |
qMAX Multiplex RT-qPCR Family Architecture
The Accuris qMAX One-Step Multiplex RT-qPCR family scales across multiplex capacity:
| Family | Multiplex capacity | List price (100-rxn No ROX) | Use case |
| PR2121 qMAX Probe One-Step | 1 target | $189 | Single-target sequence-specific RT-qPCR |
| PR2122 qMAX Probe One-Step Multiplex | 2–3 targets | $196 | Multi-target panels (target + reference; viral + control; 3-target diagnostic) |
| PR2124 qMAX Probe One-Step 4× Multiplex (this product family) | 4 targets | $196 | High-multiplex 4-target panels — viral subtyping, multi-marker diagnostic, gene expression with 3-reference normalization |
Pricing observation: PR2124 4× multiplex carries the same per-reaction price as PR2122 2–3 target multiplex ($196 at 100-rxn pack) — Accuris does NOT charge a per-target-count multiplex premium beyond the standard multiplex chemistry tier.
Why a Dedicated 4× Multiplex Master Mix
Standard 2-target multiplex master mixes can support 4-target multiplex with reasonable performance, but 4-target multiplex efficiency requires master-mix optimization:
- Higher polymerase concentration to support 4-target amplification within standard cycle counts
- Buffer composition optimized for 8-primer + 4-probe interaction (4 primer pairs = 8 oligos plus 4 probes simultaneously)
- dNTP balance matched to 4-target amplification stoichiometry
- Hot Start chemistry quality that prevents primer-dimer artifacts when 8 primers are present
- Engineered probe-fluorophore-channel non-interference — 4 fluorophores must report independently
The PR2124 master mix is engineered for these 4-target multiplex requirements.
4-Fluorophore-Channel Cycler Requirement
Critical: 4× multiplex requires a 4-fluorophore-channel qPCR cycler:
| Cycler | Channel count | 4× multiplex capable? |
| Bio-Rad CFX96 | 5 channels | ✓ Yes (4 targets + ROX channel slot) |
| Bio-Rad CFX Connect | 5 channels | ✓ Yes |
| Roche LightCycler 480 | 5 channels | ✓ Yes |
| ABI 7500 Standard | 5 channels | ✓ Yes |
| ABI ViiA 7 / QuantStudio 6/7/12K | 5–6 channels | ✓ Yes |
| Bio-Rad CFX Touch (older 4-channel) | 4 channels | ✓ Yes (no spare ROX slot) |
| Roche LightCycler 96 | 4 channels | ✓ Yes |
| Older 2-channel cyclers | 2 channels | ✗ No (insufficient for 4-target) |
Pre-procurement check: Confirm cycler has at least 4 active fluorophore channels (with the 5th typically reserved for ROX on cyclers requiring passive reference) before committing to 4× multiplex chemistry.
Pack-Size Family
| SKU | Reactions | List price | Per-reaction cost |
| PR2124-N-S | (sample) | (universe blank) | (universe blank) |
| PR2124-N-100 (this product) | 100 | $196 | $1.96/rxn |
| PR2124-N-500 | 500 | $854 | $1.71/rxn |
| PR2124-N-1000 | 1000 | (already authored) | (already authored) |
| PR2124-N-2000 / -100BLK / -50BLK | 2000+ | (already authored bulk variants) | (bulk economics) |
Application Profile
4-target pathogen detection panels — the workhorse 4× multiplex application. Multi-pathogen panels (e.g., influenza A + influenza B + RSV + internal control), multi-strain typing, multi-marker diagnostic.
Gene expression with 3-reference normalization — workflows running target gene + 3 reference genes (GAPDH, β-actin, 18S rRNA) for high-confidence normalization.
Allelic discrimination 4-target panels — multi-allele probe panels for SNP-rich genotyping.
Viral subtyping panels — multi-target panels distinguishing viral subtypes via probe-based discrimination.
Cancer-marker multiplex panels — clinical-research workflows running 4-target oncogene / suppressor-gene panels.
Method-development for high-multiplex panel design — protocol-development workflows where 4-target amplification efficiency is being optimized.
Ordering & Configuration
Probe inventory. Operator supplies 4 sequence-specific probes (each with different fluorophore label per target).
Cycler-compatibility confirmation. No ROX for non-ABI cyclers AND at least 4 active fluorophore channels required.
Storage. -20 °C, RNase-free handling, protect from light.
Confirm at quote: cycler model + channel count, multiplex panel design (4-target + fluorophore channel assignments), workflow throughput, evaluation interest (PR2124-N-S sample), and lead time.
Warranty: Per Accuris standard reagent terms — confirm at quote.
Accuris PR2124 qMAX Probe One-Step 4× Multiplex RT-qPCR No ROX family pack-size ladder:
- PR2124-N-S — sample (universe blank — confirm)
- PR2124-N-100 (this product) — 100 rxn ($196, $1.96/rxn)
- PR2124-N-500 — 500 rxn ($854, $1.71/rxn)
- PR2124-N-1000 / -2000 / -100BLK / -50BLK — production-scale and bulk packs (already authored)
Pick the 4× multiplex variant for 4-target panels; sister chemistry PR2121 (single-target) and PR2122 (2–3 target multiplex) cover lower-multiplex workflows.