Legacy Lab SuppliesPO
🔍
Accuris qMAX Probe One-Step 4× Multiplex RT-qPCR Kit, No ROX, 100 Reactions - qPCR Reagents | Legacy Lab Supplies

Accuris qMAX Probe One-Step 4× Multiplex RT-qPCR Kit, No ROX, 100 Reactions

$166.97$196.44Sale
💰 You save $29.47 vs MSRP
The PR2124-N-100 is the No ROX formulation of the Accuris qMAX Probe One-Step 4× Multiplex RT-qPCR Kit — sold as 100-reaction entry pack.
1
💰

Volume Pricing

Sign in and place an order to unlock bulk pricing.

🔄

Auto-Reorder

Unlocks with a Credit account. Contact us to apply.

📦

Bundle & Save

Unlocks with a Credit account. Contact us to apply.

Download Quick View
SKU: PR2124-N-100

The PR2124-N-100 is the No ROX formulation of the Accuris qMAX Probe One-Step 4× Multiplex RT-qPCR Kit — sold as 100-reaction entry pack. The highest-multiplex variant in the qMAX RT-qPCR family — engineered for 4-target multiplex (vs PR2122's 2–3 target capacity), supporting 4-fluorophore-channel detection in a single reaction. Same probe-based hydrolysis-probe / molecular-beacon detection chemistry as the PR2121 single-target and PR2122 2–3 target multiplex sister chemistries, but with master-mix formulation engineered for the higher-target-count multiplex efficiency requirements.

Key Specifications

SKUPR2124-N-100
TypeOne-Step 4× Multiplex RT-qPCR Kit — qMAX Probe 4× Multiplex No ROX
Pack quantity100 reactions
Multiplex capacity4 targets per reaction
Detection chemistryMulti-target probe-based — 4 fluorophore-labeled probes per reaction
ROX levelNo ROX — Bio-Rad CFX, Roche, Stratagene Mx, Eppendorf, Qiagen
Cycler requirement4-fluorophore-channel cycler (typical Bio-Rad CFX96 or higher; ABI 7500 / QuantStudio Standard configurations also support 4-channel)
Per-reaction cost$1.96 per reaction (same as PR2122 2–3 target multiplex — 4× chemistry carries no additional premium over 2–3× multiplex)
Sister chemistriesPR2121 (single-target), PR2122 (2–3 target multiplex)
Sister pack sizesPR2124-N-S (sample), PR2124-N-500 ($854), PR2124-N-1000 (already authored), PR2124-N-2000 / -100BLK / -50BLK (already authored bulk variants)
List price$196

qMAX Multiplex RT-qPCR Family Architecture

The Accuris qMAX One-Step Multiplex RT-qPCR family scales across multiplex capacity:

FamilyMultiplex capacityList price (100-rxn No ROX)Use case
PR2121 qMAX Probe One-Step1 target$189Single-target sequence-specific RT-qPCR
PR2122 qMAX Probe One-Step Multiplex2–3 targets$196Multi-target panels (target + reference; viral + control; 3-target diagnostic)
PR2124 qMAX Probe One-Step 4× Multiplex (this product family)4 targets$196High-multiplex 4-target panels — viral subtyping, multi-marker diagnostic, gene expression with 3-reference normalization

Pricing observation: PR2124 4× multiplex carries the same per-reaction price as PR2122 2–3 target multiplex ($196 at 100-rxn pack) — Accuris does NOT charge a per-target-count multiplex premium beyond the standard multiplex chemistry tier.

Why a Dedicated 4× Multiplex Master Mix

Standard 2-target multiplex master mixes can support 4-target multiplex with reasonable performance, but 4-target multiplex efficiency requires master-mix optimization:

  • Higher polymerase concentration to support 4-target amplification within standard cycle counts
  • Buffer composition optimized for 8-primer + 4-probe interaction (4 primer pairs = 8 oligos plus 4 probes simultaneously)
  • dNTP balance matched to 4-target amplification stoichiometry
  • Hot Start chemistry quality that prevents primer-dimer artifacts when 8 primers are present
  • Engineered probe-fluorophore-channel non-interference — 4 fluorophores must report independently

The PR2124 master mix is engineered for these 4-target multiplex requirements.

4-Fluorophore-Channel Cycler Requirement

Critical: 4× multiplex requires a 4-fluorophore-channel qPCR cycler:

CyclerChannel count4× multiplex capable?
Bio-Rad CFX965 channels✓ Yes (4 targets + ROX channel slot)
Bio-Rad CFX Connect5 channels✓ Yes
Roche LightCycler 4805 channels✓ Yes
ABI 7500 Standard5 channels✓ Yes
ABI ViiA 7 / QuantStudio 6/7/12K5–6 channels✓ Yes
Bio-Rad CFX Touch (older 4-channel)4 channels✓ Yes (no spare ROX slot)
Roche LightCycler 964 channels✓ Yes
Older 2-channel cyclers2 channels✗ No (insufficient for 4-target)

Pre-procurement check: Confirm cycler has at least 4 active fluorophore channels (with the 5th typically reserved for ROX on cyclers requiring passive reference) before committing to 4× multiplex chemistry.

Pack-Size Family

SKUReactionsList pricePer-reaction cost
PR2124-N-S(sample)(universe blank)(universe blank)
PR2124-N-100 (this product)100$196$1.96/rxn
PR2124-N-500500$854$1.71/rxn
PR2124-N-10001000(already authored)(already authored)
PR2124-N-2000 / -100BLK / -50BLK2000+(already authored bulk variants)(bulk economics)

Application Profile

4-target pathogen detection panels — the workhorse 4× multiplex application. Multi-pathogen panels (e.g., influenza A + influenza B + RSV + internal control), multi-strain typing, multi-marker diagnostic.

Gene expression with 3-reference normalization — workflows running target gene + 3 reference genes (GAPDH, β-actin, 18S rRNA) for high-confidence normalization.

Allelic discrimination 4-target panels — multi-allele probe panels for SNP-rich genotyping.

Viral subtyping panels — multi-target panels distinguishing viral subtypes via probe-based discrimination.

Cancer-marker multiplex panels — clinical-research workflows running 4-target oncogene / suppressor-gene panels.

Method-development for high-multiplex panel design — protocol-development workflows where 4-target amplification efficiency is being optimized.

Ordering & Configuration

Probe inventory. Operator supplies 4 sequence-specific probes (each with different fluorophore label per target).

Cycler-compatibility confirmation. No ROX for non-ABI cyclers AND at least 4 active fluorophore channels required.

Storage. -20 °C, RNase-free handling, protect from light.

Confirm at quote: cycler model + channel count, multiplex panel design (4-target + fluorophore channel assignments), workflow throughput, evaluation interest (PR2124-N-S sample), and lead time.

Warranty: Per Accuris standard reagent terms — confirm at quote.

Accuris PR2124 qMAX Probe One-Step 4× Multiplex RT-qPCR No ROX family pack-size ladder:

- PR2124-N-S — sample (universe blank — confirm)

- PR2124-N-100 (this product)100 rxn ($196, $1.96/rxn)

- PR2124-N-500 — 500 rxn ($854, $1.71/rxn)

- PR2124-N-1000 / -2000 / -100BLK / -50BLK — production-scale and bulk packs (already authored)

Pick the 4× multiplex variant for 4-target panels; sister chemistry PR2121 (single-target) and PR2122 (2–3 target multiplex) cover lower-multiplex workflows.

Authorized Distributor

Genuine, factory-warrantied units

🚚

Ships from USA

Fast domestic delivery

💬

Expert Support

Real specialists, fast response

💰

Competitive Pricing

Authorized-partner pricing

Frequently Asked Questions

Why Legacy Lab Supplies?

🏆

Authorized Dealer

We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.

💡

Expert Guidance

Not sure which model fits your lab? Our team speaks your language — we help you spec the right equipment for your exact application and budget.

📋

Procurement Made Easy

PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.

💰

Competitive Pricing

Competitive pricing every day — and we'll match any legitimate competitor price. You get premium equipment without the premium markup.

🚚

Reliable Fulfillment

Direct to your dock. You get the latest stock straight from the source — and if we don't have inventory, we work with the manufacturer to get what you need.

🤝

Long-Term Partner

Legacy Lab Supplies isn't just a transaction. We're building a long-term relationship with every lab we serve — from first quote to repeat orders.

📁 Product Documents

My Cart

🛒

Your Cart is empty

Browse Products