Legacy Lab SuppliesPO
🔍
Accuris qMAX™ Multiplex One-Step 4X RT-qPCR Kit, No ROX, 5,000 Reactions - qPCR Reagents | Legacy Lab Supplies

Accuris qMAX™ Multiplex One-Step 4X RT-qPCR Kit, No ROX, 5,000 Reactions

$4,621.53$5,437.09Sale
💰 You save $815.56 vs MSRP
The PR2124-N-50BLK is the 5,000-reaction bulk pack of the Accuris qMAX Multiplex One-Step 4X RT-qPCR Kit in the No ROX formulation — a 4× concentrated multiplex master-mix variant of the qMAX Multiplex family (sister to
1
💰

Volume Pricing

Sign in and place an order to unlock bulk pricing.

🔄

Auto-Reorder

Unlocks with a Credit account. Contact us to apply.

📦

Bundle & Save

Unlocks with a Credit account. Contact us to apply.

Download Quick View
SKU: PR2124-N-50BLK

The PR2124-N-50BLK is the 5,000-reaction bulk pack of the Accuris qMAX Multiplex One-Step 4X RT-qPCR Kit in the No ROX formulation — a 4× concentrated multiplex master-mix variant of the qMAX Multiplex family (sister to the standard 2× PR2122 kit). The 4× concentration delivers two key workflow improvements over the standard PR2122: lower per-reaction master-mix volume (master mix takes a smaller fraction of the total reaction volume, leaving more room for sample template + primers + probes) and higher-multiplex panel support (more probe sets fit in the reaction without diluting the master-mix below working concentration). The N suffix denotes No ROX; 50BLK denotes the 5,000-reaction bulk-discount pack.

Key Specifications

SKUPR2124-N-50BLK
TypeOne-Step RT-qPCR Kit — 4× concentrated multiplex probe-based
Reactions per pack5,000 reactions (bulk pack: 2 × 25 mL master mix per universe label hint — concentrated 4× formulation)
Master mix concentration4× concentrated (vs PR2122 sister kit at standard 2× concentration)
Detection chemistryHigh-multiplex probe-based real-time qPCR
Multiplexing capacityHigh-multiplex panels — typically 5+ targets per reaction with the concentrated 4× chemistry
ROX formulationNo ROX — compatible with cyclers that don't require ROX normalization
WorkflowOne-step (RNA template → high-multiplex qPCR result in one tube, one reaction setup)
Reverse transcriptaseThermostable MMLV-derived
PolymeraseAccuris Hot Start Taq with antibody-mediated hot-start activation
RNase inhibitorIncluded in optimized buffer
Cycler compatibility (No ROX)Bio-Rad CFX, Roche LightCycler, and similar real-time cyclers that don't require ROX normalization
Sister pack sizePR2124-N-100BLK (10,000 reactions, double-throughput bulk pack)

Why a 4× Concentrated Variant

The standard 2× master-mix formulation occupies half the reaction volume by design (typical 20 µL reaction = 10 µL of 2× master mix + 10 µL of sample/primers/probes/water). For high-multiplex panels (5+ targets), the primers + probes alone may exceed the available 10 µL — requiring either reaction-volume increases (which dilute the cycler's signal-readout volume) or smaller per-component volumes (which compromise primer/probe concentration optimization).

The 4× concentrated formulation allocates only 25% of the reaction volume to master mix (5 µL of 4× master mix in a 20 µL reaction), leaving 75% for sample + multiplex primer/probe sets. This enables high-multiplex panel design without reaction-volume bloat or reagent-concentration compromise.

Multiplex Family Position

KitConcentrationMultiplex capacityWhen to pick
PR2122 qMAX MultiplexStandard 2×3-5 targets per reactionMid-multiplex panels
PR2124 qMAX Multiplex 4X (this kit's family)4× concentratedHigh-multiplex panels (5+ targets)High-multiplex panel design with reaction-volume constraints

Pick the PR2124 4X variant when the multiplex panel design requires more than the standard 2× master mix's available reaction-volume allocation supports.

ROX Variant Family — N / L / H

Same convention as the rest of the qMAX family:

SuffixROX levelCompatible cyclers
N (this SKU)No ROXBio-Rad CFX, Roche LightCycler, Eppendorf Mastercycler RealPlex
LLow ROXApplied Biosystems QuantStudio (newer), Stratagene Mx3000P/Mx3005P
HHigh ROXApplied Biosystems 7000/7300/7500/7900HT (older)

Application Profile

High-multiplex pathogen detection panels — respiratory viral panels with 5-8 targets, sexually transmitted infection panels with multiple pathogen targets, gastrointestinal pathogen panels.

Comprehensive gene-expression panels — pathway-analysis workflows quantifying multiple target genes plus housekeeping genes per reaction.

Allele-specific multiplex — workflows quantifying multiple allele variants in a single reaction with high-multiplex probe sets.

Diagnostic-research-grade high-multiplex RT-qPCR — translational research workflows developing high-multiplex panels for downstream diagnostic applications.

Bulk-pack institutional procurement at high-multiplex scale — labs running >5,000 high-multiplex RT-qPCR reactions per year benefit from the bulk-pack per-reaction discount; for higher throughput, the PR2124-N-100BLK 10,000-reaction sister pack is available.

Ordering & Configuration

Storage & handling. Per kit instructions — typical RT-qPCR master mix storage at −20 °C with limited freeze-thaw cycle tolerance.

Cycler compatibility verification. Critical at order: confirm the lab's real-time cycler platform requires the No ROX formulation AND has sufficient channel capability for the high-multiplex panel design (5+ channel cyclers required for 5+ target panels).

Reaction-volume planning. The 4× concentrated formulation supports more flexible reaction-volume allocation; confirm the lab's standard reaction volume (20 µL or other) and primer/probe concentrations at order to validate the 4× chemistry matches the workflow design.

Probe procurement separately. This kit supplies the master mix; multiplex probe sets are operator-supplied.

Confirm at quote: real-time cycler platform and ROX requirement, multiplex panel design and channel count, expected workflow throughput (5,000-reaction pack vs the 10,000-reaction PR2124-N-100BLK sister), shipping conditions (cold-chain), and lead time.

Warranty: Per Accuris Life Science Reagents standard kit warranty terms — confirm at quote.

qMAX RT-qPCR family — pack-size and concentration variants:

- PR2124-N-50BLK (this product) — Multiplex 4X, 5,000 reactions

- PR2124-N-100BLK — Multiplex 4X, 10,000 reactions (double-throughput bulk pack)

- PR2122-N-50BLK — Multiplex (standard 2× concentration), 5,000 reactions

- PR2121 — Single-target Probe; PR2120 — SYBR Green

Pick the PR2124 4X concentrated variant for high-multiplex panel design where reaction-volume allocation matters.

Authorized Distributor

Genuine, factory-warrantied units

🚚

Ships from USA

Fast domestic delivery

💬

Expert Support

Real specialists, fast response

💰

Competitive Pricing

Authorized-partner pricing

Frequently Asked Questions

Why Legacy Lab Supplies?

🏆

Authorized Dealer

We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.

💡

Expert Guidance

Not sure which model fits your lab? Our team speaks your language — we help you spec the right equipment for your exact application and budget.

📋

Procurement Made Easy

PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.

💰

Competitive Pricing

Competitive pricing every day — and we'll match any legitimate competitor price. You get premium equipment without the premium markup.

🚚

Reliable Fulfillment

Direct to your dock. You get the latest stock straight from the source — and if we don't have inventory, we work with the manufacturer to get what you need.

🤝

Long-Term Partner

Legacy Lab Supplies isn't just a transaction. We're building a long-term relationship with every lab we serve — from first quote to repeat orders.

📁 Product Documents

My Cart

🛒

Your Cart is empty

Browse Products