The PR2000-N-S is the trial / sample-size SKU of the Accuris qMAX Green No ROX qPCR Master Mix family — 20-reaction pack for first-use evaluation of the No ROX chemistry on Bio-Rad CFX / Roche LightCycler / Stratagene Mx / Eppendorf realplex / Qiagen Rotor-Gene cyclers before committing to the production-scale packs.
For complete chemistry rationale and ROX-variant sample-triad procurement strategy, see the PR2000-H-S sister page.
Key Specifications
| SKU | PR2000-N-S |
| Type | Sample / trial pack — qMAX Green qPCR Master Mix, No ROX |
| Pack quantity | 20 reactions |
| ROX level | No ROX — Bio-Rad CFX, Roche, Stratagene Mx, Eppendorf, Qiagen |
| Per-reaction cost (sample) | $0.69 |
| Sister sample SKUs (all $14) | PR2000-L-S (Low ROX), PR2000-H-S (High ROX) |
| Production-scale follow-on | PR2000-N-100 ($84), PR2000-N-500 ($366), PR2000-N-1000 ($672), PR2000-N-25BLK / -50BLK (bulk) |
| List price | $14 |
ROX-Variant Sample Triad — Cycler Compatibility Validation
| Sample SKU | ROX | Compatible cycler family |
| PR2000-N-S (this product) | No ROX | Bio-Rad CFX, Roche LightCycler, Stratagene Mx, Eppendorf realplex, Qiagen Rotor-Gene |
| PR2000-L-S | Low ROX | ABI ViiA 7, QuantStudio, ABI 7500 Fast |
| PR2000-H-S | High ROX | ABI 7300 / 7500 Standard / 7700 / 7900 |
The PR2000-N-S sample is the most-frequently-ordered ROX-variant sample because Bio-Rad CFX is the dominant research-grade qPCR cycler in academic and clinical-research labs. Most labs evaluating qMAX Green chemistry start with this sample.
Application Profile
See PR2000-H-100 parent page for the full application profile.
Sample-pack validation context. The 20-reaction sample supports a complete first-use validation: confirm Bio-Rad CFX (or other No ROX cycler) compatibility (qMAX Green fluorescence detection without passive reference normalization), assay performance, and primer design.
Ordering & Configuration
Single-use sample SKU. 20-reaction pack supports a meaningful qPCR validation run.
Cycler-compatibility confirmation. Critical that No ROX matches the cycler — most non-ABI cyclers.
Confirm at quote: cycler model and ROX requirement (No ROX confirmation), evaluation intent, and lead time.
Warranty: Per Accuris standard reagent terms — confirm at quote.
Accuris qMAX Green qPCR sample triad (all $14):
- PR2000-N-S (this product) — No ROX (Bio-Rad CFX / Roche / Stratagene Mx / Eppendorf / Qiagen)
- PR2000-L-S — Low ROX (ABI ViiA 7 / QuantStudio / 7500 Fast)
- PR2000-H-S — High ROX (ABI 7300 / 7500 Standard / 7700 / 7900)
Pick the No ROX sample for Bio-Rad CFX-based labs (largest installed-base) or other non-ABI cyclers.