SmartReader™ 96 Microplate Absorbance Reader, 115V vs SmartReader™ UV-Vis Microplate Absorbance Reader with Cuvette Port, 115V

SmartReader™ 96 Microplate Absorbance Reader, 115V

SmartReader™ 96 Microplate Absorbance Reader, 115V

$6,188.66

View →
SmartReader™ UV-Vis Microplate Absorbance Reader with Cuvette Port, 115V

SmartReader™ UV-Vis Microplate Absorbance Reader with Cuvette Port, 115V

$14,940.71

View →

Which should you choose?

  • ▸If budget is the priority, SmartReader™ 96 Microplate Absorbance Reader, 115V is the lower-cost option; SmartReader™ UV-Vis Microplate Absorbance Reader with Cuvette Port, 115V lists higher and typically adds capability or capacity.

Specifications side by side

SpecSmartReader™ 96 MicroplateSmartReader™ UV-Vis Microplate
DetectorPhotodiodePhotodiode
Power input115 V (MR9600) or 230 V (MR9600-E) — discrete variantsAC 100–240 V universal, 50–60 Hz
Light sourceQuartz-halogen lamp, 6 V / 10 W (est. life 300 h)High-energy xenon flash lamp
Plate format96-well (primary supported format)—
Measurement modeVisible-spectrum absorbanceUV-Vis Absorbance (full spectrum scanning)
Wavelength range340 to 750 nm; four standard filters included (405, 450, 492, 630 nm); filter wheel holds up to 8 filters200 – 1,000 nm
Bandwidth, accuracyAccuracy at 450 nm: +/-0.005 Abs (0 to 2.0 Abs), +/-1% (2.0 to 3.0 Abs), +/-1.5% (3.0 to 4.0 Abs); precision CV <= 0.2% (0 to 3 Abs); read-out range 0.000 to 4.000 Abs, resolution 0.001 Abs—
Display—Touchscreen with on-instrument operation
Resolution—0.0001 OD
Cuvette port—Integrated single-sample cuvette read
Plate formats—6-well through 384-well
Absorbance range—0.0 – 4.0 OD
Bandwidth (FWHM)—> 2.5 nm
Dimensions / Weight—Same chassis as MR9610 (consult Accuris brochure for current dim spec)
Wavelength accuracy—± 2 nm
Wavelength repeatability—0.2 nm

Highlighted rows differ. Specs are sourced from manufacturer documentation.

FAQ

What's the difference between the SmartReader™ 96 Microplate Absorbance Reader, 115V and the SmartReader™ UV-Vis Microplate Absorbance Reader with Cuvette Port, 115V?
The main differences are in Detector, Power input, Light source. The table above shows every spec side by side; the decision guide highlights which fits which use case.
Which should I buy?
If budget is the priority, SmartReader™ 96 Microplate Absorbance Reader, 115V is the lower-cost option; SmartReader™ UV-Vis Microplate Absorbance Reader with Cuvette Port, 115V lists higher and typically adds capability or capacity.
Do both carry a warranty?
Yes, both are sold through Legacy Lab Supplies as an authorized distributor and carry full manufacturer warranty.