Legacy Lab SuppliesPO
🔍
Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF - Biological Safety Cabinets | Legacy Lab Supplies
Part of the Haier NSF Series Biological Safety Cabinet (Class II Type A2) Family · Compare all 4 models

Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF

$9,180.00$10,800.00Sale
💰 You save $1,620.00 vs MSRP
The Haier HR900-IIA2-N is a 3-foot Class II Type A2 biological safety cabinet, NSF/ANSI 49 certified, providing the three-way protection — personnel, product, and environment — that microbiology, cell culture, and clinic
1

Lead Time

6–10 Weeks

Delivery

Freight / White Glove

Warranty

Full Manufacturer Warranty Support

🔒

Authorization Hold — Not Charged Immediately

Your card is authorized at checkout. Final charge confirmed after shipping is arranged.

Download Quick View
SKU: HR900-IIA2-N

Looking at other brands too?

Compare this class of equipment spec-by-spec across our brands — same size, different manufacturer, honest guidance on which fits your application.

Compare Across Brands →

The Haier HR900-IIA2-N is a 3-foot Class II Type A2 biological safety cabinet, NSF/ANSI 49 certified, providing the three-way protection — personnel, product, and environment — that microbiology, cell culture, and clinical work with BSL-1 and BSL-2 agents require. A Class II Type A2 cabinet recirculates 70% of airflow as downflow and exhausts 30% through ULPA filtration, protecting both the operator (via the inflow air curtain) and the sample (via HEPA/ULPA-clean downflow). The HR900-IIA2-N uses ULPA U15 filters rated 99.9995% at 0.12 µm on both main and exhaust paths, an energy-efficient DC blower, and a universal 100–230 V input.

Key Specifications

SpecValue
Model (focus)Haier HR900-IIA2-N
ClassificationClass II Type A2 (NSF/ANSI 49)
Nominal size3 ft (internal width 930 mm)
Airflow circulation70% downflow / 30% exhaust
Filter typeULPA U15, 99.9995% @ 0.12 µm (main + exhaust; AAF)
Downflow / inflow velocity0.35 m/s / 0.53 m/s
BlowerDC, 190 W / 112 W
Lighting946 lux
Sound level67 dB(A)
Sash opening200 mm (max 460 mm)
Power supply100–230 V, 50/60 Hz (1300 VA)
Internal dims (W×D×H)930 × 600 × 650 mm
External dims (W×D×H)1040 × 850 (790) × 2160 mm
Support stand680 mm standard; 680–900 mm adjustable (optional)
Net/gross weight225 / 280 kg
CertificationUL, NSF
List price$10,800.00 (MSRP) — LLS price $9,180.00

Application Profile

The HR900-IIA2-N is the compact 3-foot footprint in Haier's NSF Type A2 line, sized for a single operator or a bench where floor space is limited but true containment is required. As a Class II Type A2 cabinet it is appropriate for work with microbiological and biomedical agents at BSL-1 and BSL-2 — cell and tissue culture, microbial handling, and clinical sample processing — where the ULPA-filtered downflow protects the product and the inward air curtain protects the operator. It is not designed for volatile toxic chemicals or radionuclides unless ducted appropriately; the A2 class is for biological, not chemical, containment. (See containment-classes.)

A comprehensive alarm set — abnormal inflow, abnormal downflow, filter clogging, filter damage, door-open-beyond-limit, filter and UV-lamp lifetime — makes the cabinet's protective state continuously visible, and a UV lamp supports surface decontamination between sessions. Optional GFCI sockets, side-wall service taps (gas, vacuum, air, water), a 316-SS work surface, and an antimicrobial coating tailor the cabinet to specific workflows.

Frequently Asked Questions

What containment class is the Haier HR900-IIA2-N? It is a Class II Type A2 biological safety cabinet, NSF/ANSI 49 certified, providing personnel, product, and environmental protection for BSL-1 and BSL-2 work.

How big is the 3-foot model? Internal work area is 930 × 600 × 650 mm (nominal 3 ft width); external dimensions are 1040 × 850 mm wide × 2160 mm tall including the cabinet body.

What filters does it use? ULPA U15 filters rated 99.9995% efficient at 0.12 µm on both the main (downflow) and exhaust paths, with a 70% downflow / 30% exhaust airflow split.

Can I use it for chemical fumes? No — a Type A2 cabinet is for biological containment. It should not be used for volatile toxic chemicals or radionuclides unless properly ducted; consult the containment-class guide before specifying.

What power does it need? A universal 100–230 V, 50/60 Hz input (1300 VA); the US configuration uses 115 V or 220 V/60 Hz taps within that range.

Ordering & Configuration

quote-based. The HR900-IIA2-N is a capital biosafety cabinet sold through a quote. At quote we confirm the electrical service and receptacle, floor space and ceiling clearance for the 2160 mm cabinet height, the support stand (standard 680 mm or optional adjustable), any side-wall service taps, sockets (optional GFCI), work-surface and coating options, and certification/field-validation needs. Warranty terms are confirmed with the quote, and lead time is provided at quotation. Request a quote to configure the HR900-IIA2-N for your lab.

Sizing the NSF Type A2 line: the HR900-IIA2-N is the 3-foot cabinet for single-operator or space-limited benches. Step up to the HR1200-IIA2-N (4 ft), HR1500-IIA2-N (5 ft), or HR1800-IIA2-N (6 ft) for wider work areas and multi-operator use. Pair the 4-foot cabinet with the matching adjustable Stand-4FT.

Authorized Distributor

Genuine, factory-warrantied units

🚚

Ships from USA

Fast domestic delivery

💬

Expert Support

Real specialists, fast response

💰

Competitive Pricing

Authorized-partner pricing

Frequently Asked Questions

Why Legacy Lab Supplies?

🏆

Authorized Dealer

We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.

💡

Expert Guidance

Not sure which model fits your lab? Our team speaks your language — we help you spec the right equipment for your exact application and budget.

📋

Procurement Made Easy

PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.

💰

Competitive Pricing

Competitive pricing every day — and we'll match any legitimate competitor price. You get premium equipment without the premium markup.

🚚

Reliable Fulfillment

Direct to your dock. You get the latest stock straight from the source — and if we don't have inventory, we work with the manufacturer to get what you need.

🤝

Long-Term Partner

Legacy Lab Supplies isn't just a transaction. We're building a long-term relationship with every lab we serve — from first quote to repeat orders.

📁 Product Documents

Common Questions

How much does the Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF cost?+

The Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF (HR900-IIA2-N) is $10,800.00 at Legacy Lab Supplies, with transparent pricing shown up front — no login or quote required.

Does the Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF come with a manufacturer warranty?+

Yes. Legacy Lab Supplies is an authorized Haier Biomedical distributor, so every Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF ships new with the full Haier Biomedical factory warranty.

What are the key specifications of the Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF?+

Key specifications of the Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF: Spec: Value; Blower: DC, 190 W / 112 W; Lighting: 946 lux; Filter type: ULPA U15, 99.9995% @ 0.12 µm (main + exhaust; AAF). The complete manufacturer specification table is on this page.

How does the Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF ship?+

The Haier HR900-IIA2-N Class II Type A2 Biosafety Cabinet, 3 ft, NSF ships by freight carrier on a pallet. Liftgate and white-glove delivery options are available, and freight cost is confirmed on your quote or at checkout. Current lead time: Unknown.

My Cart

🛒

Your Cart is empty

Browse Products