The Z216-24SC is the 24-position spin column kit rotor for the Hermle Z216 series chassis (Z216-M and Z216-MK) — engineered for silica- and membrane-based spin column extraction kits (Qiagen, Zymo Research, Promega, Bio-Rad, NEB and equivalent commercial kit chemistries). Spin columns combine a column body (filter membrane on a frit) with a 1.5 / 2.0 mL collection tube; the column-plus-tube assembly is taller than a standard microtube alone — the SC rotor geometry accommodates this taller stack with the correct hub depth and spindle clearance on the Z216 series chassis.
Universe class flag: The universe price list classifies this SKU as
consumable, but the SKU is functionally a rotor (sister to the class=accessory Z207-24SC and Z287-24SC rotor SKUs at similar pricing on Z207-M and Z287-A chassis respectively). Flagging for post-launch class correction toaccessory.
| SKU | Z216-24SC |
| Type | Fixed-angle spin column rotor — 24 position |
| Capacity | 24 × 1.5 / 2.0 mL spin column kit assemblies |
| Compatible chassis | Z216 series — Z216-M, Z216-MK (refrigerated), and -E voltage variants |
| Angle | 45° |
| Lid | Hermetically sealed |
| Sample compatibility | Standard 1.5 / 2.0 mL spin column + collection tube assemblies — silica, anion-exchange, size-exclusion, affinity-bead column formats |
| Adapter compatibility | C1008-A5-6 (0.5 mL); C1008-A2-6 (0.4/0.2 mL PCR) — for downstream microtube use |
Standard silica and membrane spin columns from major commercial extraction kits seat into the SC rotor positions:
The rotor geometry accepts standard column body dimensions (typical column OD ~9–11 mm; standard collection tube format 1.5 / 2.0 mL). Confirm at order if the workflow uses non-standard column dimensions (some specialty kits use proprietary geometries).
Standard microtube rotors on the Z216 series (Z216-2420, Z216-2420H, Z216-COMBI-Rotor) are dimensioned for the microtube alone. Spin column assemblies stack the column body on top of the collection tube, increasing total height — the SC rotor's hub depth and spindle clearance accommodate this stack while maintaining the 45° angle and balanced rotation. Running spin columns in a non-SC microtube rotor is a fit problem (column may not seat fully) and a balance problem (irregular column-body weight distribution at the high-RCF range the Z216 series delivers).
The hermetically sealed lid supports BSL-2 + extraction workflows where aerosol containment matters (extraction protocols handling potentially infectious patient samples for diagnostic or research workflows).
Routine DNA / RNA extraction at clinical-research and core-facility scale on Z216 series — the dominant use case. Most commercial extraction kits center on the silica spin-column workflow; the Z216 series + Z216-24SC combination delivers clean prep for downstream PCR, qPCR, sequencing, and microarray assays at the high-speed Z216 chassis range.
24-sample batches per cycle — matches the typical 96-well plate quadrant batch size (24 = 1/4 of a 96-well plate) common in extraction prep workflows.
Pre-PCR and pre-qPCR sample prep — extract DNA / RNA into the SC rotor, then transfer eluate to PCR plate or strip for amplification.
Gel and PCR cleanup — post-amplification or post-restriction-digest cleanup using gel-extraction or PCR-cleanup column kits.
Plasmid mini-prep — bacterial-culture-derived plasmid prep for cloning workflows; the SC rotor handles the typical 24-clone screening batch in a single cycle.
Cold-chain extraction workflows on Z216-MK — refrigerated extraction prep when the workflow requires cold-chain integrity through the spin column elution step.
BSL-2 + extraction workflows — when extraction protocols handle potentially infectious patient samples requiring aerosol containment via the hermetic lid.
24-position symmetric loading. Pair opposites by mass; spin column assemblies have variable mass during the workflow — column with binding buffer is heavier than column with eluate — so re-balance pairs at each spin step in a multi-step extraction protocol.
Hermetic-seal engagement. The hermetically sealed lid must be fully engaged before each spin to maintain the seal at the rotor's high RCF.
Selectable accel/decel. Z216 chassis profiles apply; the unbraked extended-decel profile preserves loose silica-bound material during the elution step.
Z216-24SC ships as the rotor body + lid. Spin column kits, reagents, and adapters for downstream microtube use (C1008-A5-6, C1008-A2-6) are sold separately or supplied per the user's chosen kit.
Confirm at quote: chassis pairing (Z216-M or Z216-MK), kit chemistry intended (most major kits compatible — confirm if using non-standard column geometry), workflow biosafety driver (hermetic lid supports BSL-2 + workflows), and lead time.
Warranty: 5-Year Hermle warranty (3 years full + 2 years drivetrain) on the rotor body and lid.
Spin column rotor selection across Hermle chassis families:
- Z216-24SC (this product) — Z216 series chassis (high-speed microcentrifuge platform with hermetic-seal lid)
- Z207-24SC — Z207-M chassis (compact microcentrifuge)
- Z287-24SC — Z287-A chassis (compact universal)
Pick the Z216-24SC when the lab's extraction workflow runs on the Z216 series chassis and needs the hermetic-seal lid for biosafety containment.
Authorized Distributor
Genuine, factory-warrantied units
Ships from USA
Fast domestic delivery
Expert Support
Real specialists, fast response
Competitive Pricing
Authorized-partner pricing
We are an authorized distributor for Yamato Scientific, Haier Biomedical, Scientemp, Benchmark Scientific, and True Scientific. Every unit comes with full manufacturer warranty and factory support.
Not sure which model fits your lab? Our team speaks your language — we help you spec the right equipment for your exact application and budget.
PO-friendly, quote-ready, and net-term capable. We work with universities, hospitals, and government labs every day. No friction, no hassle.
Competitive pricing every day — and we'll match any legitimate competitor price. You get premium equipment without the premium markup.
Direct to your dock. You get the latest stock straight from the source — and if we don't have inventory, we work with the manufacturer to get what you need.
Legacy Lab Supplies isn't just a transaction. We're building a long-term relationship with every lab we serve — from first quote to repeat orders.