Skip to main content
Legacy Lab SuppliesPO
🔍

Turbo™ 2D Gradient Thermal Cycler, 115V vs Benchmark TC9639 Thermal Cycler with Multi-Format Block, 115 V

Turbo™ 2D Gradient Thermal Cycler, 115V

Turbo™ 2D Gradient Thermal Cycler, 115V

$9,264.07

View →
Benchmark TC9639 Thermal Cycler with Multi-Format Block, 115 V

Benchmark TC9639 Thermal Cycler with Multi-Format Block, 115 V

$5,554.37

View →

Which should you choose?

  • ▸If budget is the priority, Benchmark TC9639 Thermal Cycler with Multi-Format Block, 115 V is the lower-cost option; Turbo™ 2D Gradient Thermal Cycler, 115V lists higher and typically adds capability or capacity.
  • ▸Different manufacturers (Benchmark Scientific vs Accuris), both carry full manufacturer warranty through us.

Specifications side by side

SpecTurbo™ 2D GradientBenchmark TC9639 Thermal
DisplayLarge full-color touchscreenLarge full-color touch screen with program wizard
StorageUnlimited program storage; public folders, password-protected folders, or USB flash drive transfer—
Heated lidYes — fully adjustable—
Block formatMulti-format: 96 × 0.2 mL tubes or strips, 39 × 0.5 mL tubes, or 96-well plate—
Program inputProgram Wizard (single-screen guided protocol setup) + virtual keyboard for alphanumeric naming—
Gradient capability2D gradient — temperature gradient in two dimensions across the block—
Programming featuresTime and temperature increments per step; adjustable ramp rates—
Glove-compatible operationTouchscreen works with gloves on—
Type—Thermal cycler with multi-format sample block
Class—Capital — thermal cycler
Weight—16 lbs / 7.3 kg
Dimensions—10.2 × 14.2 × 9.9 in / 26 × 36 × 25 cm (W × D × H)
Power supply—Universal 75–275 V, 50/60 Hz (chassis accepts both voltages — only plug differs between -96 variants)
Communication—USB, LAN, RS232
Program memory—Unlimited with flash drive (programs stored in public folders, password-protected folders, or flash drive)
In-situ adapter—T5000-A-IS (4 slides — fits T5000-96 multi-format block)
Maximum ramp rate—4 °C/second
Accuracy / uniformity—±0.2 °C / ±0.2 °C
Power failure restart—Yes
Sample block capacity—96 × 0.2 mL tubes/strip tubes OR 39 × 0.5 mL tubes OR 1 nonskirted 96-well plate
Heated lid temperature—30 - 112°C (user adjustable; auto-shuts off when block < 35°C)
Increments / decrements—Yes — time AND temperature
Temperature control mode—Simulated sample OR block (operator-selectable)
Temperature control range—0 - 100°C

Highlighted rows differ. Specs are sourced from manufacturer documentation.

FAQ

What's the difference between the Turbo™ 2D Gradient Thermal Cycler, 115V and the Benchmark TC9639 Thermal Cycler with Multi-Format Block, 115 V?
The main differences are in Display, Storage, Heated lid. The table above shows every spec side by side; the decision guide highlights which fits which use case.
Which should I buy?
If budget is the priority, Benchmark TC9639 Thermal Cycler with Multi-Format Block, 115 V is the lower-cost option; Turbo™ 2D Gradient Thermal Cycler, 115V lists higher and typically adds capability or capacity.
Do both carry a warranty?
Yes, both are sold through Legacy Lab Supplies as an authorized distributor and carry full manufacturer warranty.

Email me this comparison

Get this side-by-side plus our buying guide for this category. No spam.

Still deciding? Our team compares options with you, no pressure.