Haier HYC-461FD +2 to +8 °C Pharmacy Refrigerator, 461 L / 16.3 cf, Solid Door vs Haier HYC-1378 Double-Door Pharmacy Refrigerator, 115V
Which should you choose?
- ▸If budget is the priority, Haier HYC-461FD +2 to +8 °C Pharmacy Refrigerator, 461 L / 16.3 cf, Solid Door is the lower-cost option; Haier HYC-1378 Double-Door Pharmacy Refrigerator, 115V lists higher and typically adds capability or capacity.
- ▸Capacity: Haier HYC-461FD +2 to +8 °C Pharmacy Refrigerator, 461 L / 16.3 cf, Solid Door is "461 L / 16.3 cu ft" vs Haier HYC-1378 Double-Door Pharmacy Refrigerator, 115V at "1378 L / 48.7 cu ft", match this to your application.
Specifications side by side
| Spec | Haier HYC-461FD +2 | Haier HYC-1378 Double-Door |
|---|---|---|
| Weight | 254 lb (115 kg) | 683.4 lb (310 kg) |
| Shelves | 6 adjustable plastic-coated wire shelves (per brochure) | 12 adjustable, plastic-coated wire |
| Capacity | 461 L / 16.3 cu ft | 1378 L / 48.7 cu ft |
| Refrigerant | R600a (HC) | R290 |
| Sound level | 37 dB(A) | 45 dB(A) |
| Cabinet type | Upright, solid door | Upright, double glass door |
| Power supply | 115 V, 60 Hz | — |
| Certification | UL, ENERGY STAR | UL |
| Climate class | N (16–32 °C ambient) | N |
| Crated weight | 276 lb (125 kg) | 793.7 lb (360 kg) |
| Model (focus) | Haier HYC-461FD (solid door) | — |
| Power / current | 230 W / 3.1 A | — |
| Cooling / defrost | Forced-air cooling, automatic defrost | — |
| Temperature range | +2°C to +8°C | +2°C to +8°C |
| Packing dimensions | 28.3 x 36.6 x 82.7 in (720 x 930 x 2100 mm) | — |
| External dimensions | 23.4 x 31.5 x 78.3 in (595 x 800 x 1990 mm) | 56.7 x 37.4 x 78.0 in (1440 x 950 x 1980 mm) |
| Internal dimensions | 19.7 x 23.2 x 65.7 in (500 x 590 x 1670 mm) | 52.0 x 27.6 x 59.1 in (1320 x 700 x 1500 mm) |
| Controller / display | Microprocessor, LED (0.1 °C resolution) | Microprocessor, LED (0.1°C resolution) |
| Temperature uniformity | ≤ ±1.5°C | — |
| Doors | — | 2 glass doors (heated double-pane, self-closing) |
| Alarms | — | High/low temp, remote alarm, power failure, sensor error, low battery, door ajar, audible/visual |
| Cooling | — | Forced-air, auto defrost, hydrocarbon (R290) refrigerant |
| Voltage | — | 115V |
| Amperage | — | 7.5 A |
Highlighted rows differ. Specs are sourced from manufacturer documentation.
FAQ
- What's the difference between the Haier HYC-461FD +2 to +8 °C Pharmacy Refrigerator, 461 L / 16.3 cf, Solid Door and the Haier HYC-1378 Double-Door Pharmacy Refrigerator, 115V?
- The main differences are in Weight, Shelves, Capacity. The table above shows every spec side by side; the decision guide highlights which fits which use case.
- Which should I buy?
- If budget is the priority, Haier HYC-461FD +2 to +8 °C Pharmacy Refrigerator, 461 L / 16.3 cf, Solid Door is the lower-cost option; Haier HYC-1378 Double-Door Pharmacy Refrigerator, 115V lists higher and typically adds capability or capacity.
- Do both carry a warranty?
- Yes, both are sold through Legacy Lab Supplies as an authorized distributor and carry full manufacturer warranty.
Still deciding? Our team compares options with you, no pressure.