Skip to main content
Legacy Lab SuppliesPO
๐Ÿ”

Haier HR1200-IIA2-N 4-ft Class II Type A2 Biosafety Cabinet vs Haier HR1800-IIA2-N Class II Type A2 Biosafety Cabinet, 6 ft, NSF

Haier HR1200-IIA2-N 4-ft Class II Type A2 Biosafety Cabinet

Haier HR1200-IIA2-N 4-ft Class II Type A2 Biosafety Cabinet

$10,455.00

View โ†’
Haier HR1800-IIA2-N Class II Type A2 Biosafety Cabinet, 6 ft, NSF

Haier HR1800-IIA2-N Class II Type A2 Biosafety Cabinet, 6 ft, NSF

$12,495.00

View โ†’

Which should you choose?

  • โ–ธIf budget is the priority, Haier HR1200-IIA2-N 4-ft Class II Type A2 Biosafety Cabinet is the lower-cost option; Haier HR1800-IIA2-N Class II Type A2 Biosafety Cabinet, 6 ft, NSF lists higher and typically adds capability or capacity.

Specifications side by side

SpecHaier HR1200-IIA2-N 4-ftHaier HR1800-IIA2-N Class
Power1300 VAโ€”
AlarmsSound + flash: door ajar, abnormal inflow/downflow, filter clogging/damage/lifetime, UV lampโ€”
Weight617 lb (275 kg)827 lb (375 kg)
FiltrationULPA U15, 99.9995% @ 0.12 ยตm (AAF), main + exhaustโ€”
Sound level64 dB(A)67 dB(A)
Power supply100-230V/50-60Hz (US 115V; 220V available)100โ€“230 V, 50/60 Hz (1400 VA)
Sash opening200 mm (max 460 mm)200 mm (max 460 mm)
Cabinet classClass II Type A2โ€”
CertificationUL, NSFUL, NSF
Crated weight750 lb (335 kg)1014 lb (460 kg)
Nominal width4 ft (1230 mm internal work width)โ€”
Inflow velocity0.53 m/sโ€”
Downflow velocity0.35 m/sโ€”
Outlets / features2 sockets (optional GFCI), armrest, UV lamp, one-piece work surfaceโ€”
Packing dimensions56.5 x 37.2 x 66.9 in (1435 x 945 x 1700 mm)80.2 x 37.2 x 66.9 in (2038 x 945 x 1700 mm)
Airflow circulation70% downflow / 30% exhaust70% downflow / 30% exhaust
Internal dimensions48.4 x 23.6 x 25.6 in (1230 x 600 x 650 mm)72.0 x 23.6 x 25.6 in (1830 x 600 x 650 mm)
Blowerโ€”DC, 120 W / 112 W
Lightingโ€”1292 lux
Filter typeโ€”ULPA U15, 99.9995% @ 0.12 ยตm (main + exhaust; AAF)
Nominal sizeโ€”6 ft (internal width 1830 mm)
Model (focus)โ€”Haier HR1800-IIA2-N
Support standโ€”680 mm standard; 680โ€“900 mm adjustable (optional)
Classificationโ€”Class II Type A2 (NSF/ANSI 49)

Highlighted rows differ. Specs are sourced from manufacturer documentation.

FAQ

What's the difference between the Haier HR1200-IIA2-N 4-ft Class II Type A2 Biosafety Cabinet and the Haier HR1800-IIA2-N Class II Type A2 Biosafety Cabinet, 6 ft, NSF?
The main differences are in Power, Alarms, Weight. The table above shows every spec side by side; the decision guide highlights which fits which use case.
Which should I buy?
If budget is the priority, Haier HR1200-IIA2-N 4-ft Class II Type A2 Biosafety Cabinet is the lower-cost option; Haier HR1800-IIA2-N Class II Type A2 Biosafety Cabinet, 6 ft, NSF lists higher and typically adds capability or capacity.
Do both carry a warranty?
Yes, both are sold through Legacy Lab Supplies as an authorized distributor and carry full manufacturer warranty.

Email me this comparison

Get this side-by-side plus our buying guide for this category. No spam.

Still deciding? Our team compares options with you, no pressure.