Haier HCP-168B CO2 Incubator, 180°C Dry-Heat Sterilization, 115V vs Haier HCP-80B CO₂ Incubator, 80 L / 2.8 cf, 180 °C Dry-Heat Sterilization
Which should you choose?
- ▸If budget is the priority, Haier HCP-80B CO₂ Incubator, 80 L / 2.8 cf, 180 °C Dry-Heat Sterilization is the lower-cost option; Haier HCP-168B CO2 Incubator, 180°C Dry-Heat Sterilization, 115V lists higher and typically adds capability or capacity.
Specifications side by side
| Spec | Haier HCP-168B CO2 | Haier HCP-80B CO₂ |
|---|---|---|
| Weight | 209.4 lb (95 kg) | 165 lb (75 kg) |
| Heating | Six-sided, fuzzy-PID; 2× PT1000 sensors | — |
| Options | HEPA filtration, roller base, O₂ module, IoT, humidity display, electromagnetic lock | — |
| Shelves | 3 standard / 11 max, perforated adjustable (15 kg/shelf) | 3 standard / 8 max, perforated adjustable (380 × 300 mm, 15/45 kg) |
| Voltage | 115V | — |
| Humidity | RH 93% ±3% @ 37°C, water reservoir up to ~3.5 L | — |
| Recovery | Temp & CO₂ recover within ~4 min after 30 s door open | — |
| Access port | 42 mm diameter | — |
| Certification | UL (US 115/60) | — |
| Crated weight | 286.6 lb (130 kg) | 209 lb (95 kg) |
| Sterilization | 180°C dry-heat, under 12 hours, all interior surfaces | 180 °C dry-heat, all surfaces, under 12 h |
| Chamber volume | 170 L / 6.0 cu ft | 80 L / 2.8 cu ft |
| Temperature range | Ambient +3°C to 55°C | Ambient +3°C to 55°C |
| Packing dimensions | 31.5 x 35.0 x 41.3 in (800 x 890 x 1050 mm) | 27.6 x 30.3 x 35.8 in (700 x 770 x 910 mm) |
| External dimensions | 28.1 x 32 x 34.9 in (714 x 812 x 887 mm) | — |
| Interior / exterior | 304 stainless steel / powder-coated cold-rolled steel | — |
| Internal dimensions | 19.3 x 22 x 25.6 in (490 x 560 x 650 mm) | 15.7 x 16.5 x 19.3 in (400 x 420 x 490 mm) |
| Controller / display | Microprocessor, 7-inch LCD touchscreen | Microprocessor, 7-inch LCD |
| CO₂ range / control | 0-20%, IR sensor, ±0.10% accuracy | — |
| Temperature control / uniformity | ±0.1°C fluctuation, ±0.3°C uniformity | — |
| Type | — | Air-jacket CO₂ incubator |
| Data outputs | — | USB, remote alarm contacts |
| Power supply | — | 115 V, 60 Hz |
| Air treatment | — | HEPA filter |
Highlighted rows differ. Specs are sourced from manufacturer documentation.
FAQ
- What's the difference between the Haier HCP-168B CO2 Incubator, 180°C Dry-Heat Sterilization, 115V and the Haier HCP-80B CO₂ Incubator, 80 L / 2.8 cf, 180 °C Dry-Heat Sterilization?
- The main differences are in Weight, Heating, Options. The table above shows every spec side by side; the decision guide highlights which fits which use case.
- Which should I buy?
- If budget is the priority, Haier HCP-80B CO₂ Incubator, 80 L / 2.8 cf, 180 °C Dry-Heat Sterilization is the lower-cost option; Haier HCP-168B CO2 Incubator, 180°C Dry-Heat Sterilization, 115V lists higher and typically adds capability or capacity.
- Do both carry a warranty?
- Yes, both are sold through Legacy Lab Supplies as an authorized distributor and carry full manufacturer warranty.