MultiCycler 248 Dual Block Thermal Cycler , Universal 120–240 V vs Benchmark TC9639 Thermal Cycler with Multi-Format Block , 115 V
Which should you choose?
- ▸If budget is the priority, Benchmark TC9639 Thermal Cycler with Multi-Format Block , 115 V is the lower-cost option; MultiCycler 248 Dual Block Thermal Cycler , Universal 120–240 V lists higher and typically adds capability or capacity.
- ▸Different manufacturers (Benchmark Scientific vs Accuris) — both carry full manufacturer warranty through us.
Specifications side by side
| Spec | MultiCycler 248 Dual | Benchmark TC9639 Thermal |
|---|---|---|
| Type | Dual-block independent thermal cycler | Thermal cycler with multi-format sample block |
| Class | Capital — durable bench instrument | Capital — thermal cycler |
| Blocks | 2 (independent thermal control) | — |
| Voltage | Universal 120–240 V, 50–60 Hz | — |
| Weight | — | 16 lbs / 7.3 kg |
| Display | — | Large full-color touch screen with program wizard |
| Dimensions | — | 10.2 × 14.2 × 9.9 in / 26 × 36 × 25 cm (W × D × H) |
| Power supply | — | Universal 75–275 V, 50/60 Hz (chassis accepts both voltages — only plug differs between -96 variants) |
| Communication | — | USB, LAN, RS232 |
| Program memory | — | Unlimited with flash drive (programs stored in public folders, password-protected folders, or flash drive) |
| In-situ adapter | — | T5000-A-IS (4 slides — fits T5000-96 multi-format block) |
| Maximum ramp rate | — | 4 °C/second |
| Accuracy / uniformity | — | ±0.2 °C / ±0.2 °C |
| Power failure restart | — | Yes |
| Sample block capacity | — | 96 × 0.2 mL tubes/strip tubes OR 39 × 0.5 mL tubes OR 1 nonskirted 96-well plate |
| Heated lid temperature | — | 30 - 112°C (user adjustable; auto-shuts off when block < 35°C) |
| Increments / decrements | — | Yes — time AND temperature |
| Temperature control mode | — | Simulated sample OR block (operator-selectable) |
| Temperature control range | — | 0 - 100°C |
| Sister SKU (384-well block) | — | T5000-384 (single 384-well plate block, $7,607) |
Highlighted rows differ. Specs are sourced from manufacturer documentation.
FAQ
- What's the difference between the MultiCycler 248 Dual Block Thermal Cycler , Universal 120–240 V and the Benchmark TC9639 Thermal Cycler with Multi-Format Block , 115 V?
- The main differences are in Type, Class, Blocks. The table above shows every spec side by side; the decision guide highlights which fits which use case.
- Which should I buy?
- If budget is the priority, Benchmark TC9639 Thermal Cycler with Multi-Format Block , 115 V is the lower-cost option; MultiCycler 248 Dual Block Thermal Cycler , Universal 120–240 V lists higher and typically adds capability or capacity.
- Do both carry a warranty?
- Yes — both are sold through Legacy Lab Supplies as an authorized distributor and carry full manufacturer warranty.
Still deciding? Our team compares options with you — no pressure.